Earth Connection: 

 

-Connect the chassis ground first

!! 

 

-Lay the flexible chassis ground cable from the chassis of the vehicle to 
the chassis ground on the rack of the inverter.  
-Connect the chassis ground.  

Reverse polarity connection of the battery wires can damage the 

inverter. Do not use the inverter with electrical systems using positive 
ground.  

 
AC input/output cable connection: 

Connecting the ac wire: 
- Black is Hot 
- White is Neutral 
- Green is Ground 
-Connect the chassis ground first

!! 

 

Make sure not to mix up the input and output. The input is your city utility 
power company. Make sure it is not Live as you are working on the 
connections. Inverter must also be OFF and/or disconnected from 
battery(ies). 

 

Recommendation: prior to connecting the ac output, we recommend you 
power up the inverter and have a meter on the AC output to ensure all is 
operating properly. If you get the 110-120Vac Output, then turn 
off/disconnect ac power source and turn off the inverter, then make 
output connection. 
 

!

 Make sure there is no AC output (inverter off and no ac in) before 

connecting to ac out. We recommend measuring AC output with an AC 
volt meter prior to wiring. Ensure all cables and wires are connected 
properly and are in good condition prior to use. 
 

Connection to the AC socket: 

Insert the inverter AC cable to power socket. 
 
 

Summary of Contents for APT1200-12

Page 1: ......

Page 2: ...ance or a combination of appliances run a test All inverters are designed to automatically shut down in the event of a power overload This protection feature prevents damage to the unit while running...

Page 3: ...le Keep the area surrounding the inverter clear to ensure free air circulation around the unit Do not place items on or over the inverter during operation The unit will shut down if the internal tempe...

Page 4: ...be calculated from amperes amps This information is usually stamped or printed on most appliances and equipment If this information is not indicated on the appliance or equipment check the owner s ma...

Page 5: ...inals of the inverter take cable cross section from the table Connect first the negative then the positive cable Make sure the terminals are not reversed Reverse polarity connection will blow the inte...

Page 6: ...ty power company Make sure it is not Live as you are working on the connections Inverter must also be OFF and or disconnected from battery ies Recommendation prior to connecting the ac output we recom...

Page 7: ...n inverter and disconnect Clean terminals thoroughly and reconnect Blown DC battery fuse s Turn off inverter Fix problem Replace fuse s with same type and rating PROBLEM Inverter is Shut Down Reason S...

Page 8: ...ty Peak Power 2000W Rated Input DC V A 13VDC 110A Rated Input AC V A 120VAC 10 12A Input Voltage Range 10 5 to 15 5 VDC 10 AC Input Frequency Hz 60 5Hz Inverter Output Frequency Hz 60 0 1Hz Rated Outp...

Page 9: ...e right to use parts or products of original or improved design in the repair or replacement If Power Bright repairs or replaces a product its warranty continues for the remaining portion of the origi...

Page 10: ...put voltage from generators and lightning strikes 3 the product if repairs have been done to it other than by Power Bright or its authorized service centers hereafter ASCs 4 the product if it is used...

Page 11: ...al number of your product Information about the installation and use of the unit Information about the failure and or reason for the return A copy of your dated proof of purchase Return Procedure 1 Pa...

Reviews: