Error codes
The error codes help you do troubleshooting on the
battery pack and/or the battery charger while it charges.
Note: Look at the battery state of charge LED with the
ribs of the battery pointed up to see the correct
orientation of the LED lights.
LED screen
Possible faults
Possible steps
LED 1 is red and LED 4 is
green, battery pack does not
charge or operate correctly in
product
Internal fuse is blown
Speak to an approved service center.
LED 1 is red
Irregular cell voltage
Speak to an approved service center.
LED 4 is green
Battery pack is over-
charged
Remove the battery pack from the battery charger and in-
stall in the product. Operate the product. Battery charger
may be defective. Speak to an approved service center.
LED 1 is red and LED 2 is
green, battery pack does not
charge or operate correctly in
product
Battery pack failure
Remove battery pack from the product. Do not charge.
Battery pack is damaged and must be replaced. Speak to
an approved service center.
RED LED comes on, LED 2
is green and flashes during
charging or when the battery
pack is in the battery charger
Internal battery tempa-
ture is too low or too
high for charging
Move the battery charger and battery pack to a location
where the internal temperature of the battery pack can be
between 5°C (41°F) and 45°C (113°F).
RED LED flashes and LED 2
flashes green when the bat-
tery pack is installed.
Internal battery tempera-
ture is too low or too
high
The internal temperature in the battery must be between
-15°C (5°F) and 70°C (158°F). The environment tempera-
ture in the battery pack is too low or too high.
• If the battery pack is too cold from the ambient envi-
ronment, move the battery pack and battery charger to
a warm environment.
• If the battery pack is too hot, especially after operation,
move the battery pack and battery charger away from
the hot environment.
TECHNICAL DATA
unit
PRCS16i
(BCS58VPR)
Motor specifications
Motor type
Brushless
Motor voltage
V (DC)
58
Motor power
W
2000
18
319 - 002 - 17.11.2017