Tab.20 Maximum length for configuration C
13
Configuration
Unit
SIRIUS THREE FS 50 SIRIUS THREE FS
70
SIRIUS THREE FS 90 SIRIUS THREE FS
110
mm
Ø 80 / Ø 125
Ø 80 / Ø 125
Ø 110 / Ø 160
Ø 110 / Ø 160
1
m
L<10 m
L<10 m
L<10 m
L<10 m
2
m
L<10 m
L<10 m
L<10 m
L<10 m
3
m
L<9 m
L<9 m
L<9 m
L<9 m
4
m
L<9 m
L<9 m
L<9 m
L<9 m
Configuration C
33
Important
Pipes subject to technical evaluation 14 08–1289.
Tab.21 Maximum length for configuration C
33
Configuration
Unit
SIRIUS THREE FS 50 SIRIUS THREE FS
70
SIRIUS THREE FS 90 SIRIUS THREE FS
110
mm
Ø 80 / Ø 125
Ø 80 / Ø 125
Ø 110 / Ø 160
Ø 110 / Ø 160
5
m
L<10 m
L<10 m
L<10 m
L<10 m
6
m
L<10 m
L<10 m
L<10 m
L<10 m
7
m
L<8 m
L<8 m
L<8 m
L<8 m
8
m
L<9 m
L<9 m
L<9 m
L<9 m
Fig.52
Maximum length of the connections
MW
-3
0
0
0
0
3
3
-0
2
1
3
4
L
L
L
L
2
Fig.53
Maximum length of the connections
MW
-3
0
0
0
1
7
2
-0
1
L
L
L
L
5
7
8
6
6 Installation
46
7609493 - v08 - 24072018