91.7.1 - GB/IE
InstructIons pErtaInInG to thE InstaLLEr
APPLICATION
TERMINAL BOARD
PRIMARY PUMP PLP
M1: A – B
DHW PUMP PDHW
M3: 13 – 14
HEATING PUMP P1
M3: 11 – 12
DHW SENSOR TS
M2: 7 – 8
REMOTE CONTROL QAA73 (LOW TEMPERATURE)
M2: 1 – 2
ROOM THERMOSTAT
M2: 3 – 4
HEATING PUMP P2
CLIP IN AGU 2.500
3 WAY VALVE
CLIP IN AGU 2.500
FLOW SENSOR
CLIP IN AGU 2.500
Applications (pumps, sensor, remote control ...) have to be connected to terminal as follows (see also section
14):
Parameter changes requires (see also section 16):
PCB
Description
Setting Parameter
PARAMETER
H552
Hydraulic system
H552 = 50
H553
KonfigHKS
H553 = 12
H615
KonfigAusgang
H615 = 9
H632
Wanfo Q8
H632 = 00001111
13.3 Heat excHanger pressure drop
kpa
Lit/sec
kpa
Lit/sec
kpa
Lit/sec
kpa
Lit/sec
Wh50
70,61
0,98
31,38
0,72
11,77
0,54
10,79
0,36
Wh0
61,78
1,19
30,40
0,88
17,65
0,66
12,26
0,44
Wh70
56,88
1,41
34,32
1,04
20,59
0,78
11,77
0,52
Boiler
hydraulic resistance and Water Flow rates
11°c ∆t
15°c ∆t
0°c ∆t
0°c ∆t
Wh50
0,28
Wh0
0,28
Wh70
0,35
Boiler
Minimum Water Flow rates
Lit/sec