Commissioning the Boiler - Combustion Check
1
. Reference should be made to BS:EN
1
2
8
2
8
&
1
4336
when commissioning the boiler.
2. At the time of commissioning, complete all relevant
sections of the Benchmar
k
C
hec
k
list at the rear of this
publications.
3. Having chec
k
ed:
• That the boiler has been installed in accordance with
these instructions.
• The integrity of the flue system and the flue seals.
• The integrity of the boiler combustion circuit and the
relevant seals.
P
roceed to put the boiler into operation as follows:
4.
The Combustion Check procedure as shown by the
chart on the next page is mandatory. The method of
setting the boiler to operate at maximum and
minimum rates to comply with the procedure is
described below.
5
. Ensure that all external controls are calling for heat.
The actual current boiler temperature is shown on the
display.
6. Turn both control
k
nobs fully anticloc
k
wise, then quic
k
ly
turn the right hand
k
nob
1
/4 cloc
k
wise twice and bac
k
fully anticloc
k
wise.
7
. The display will now alternate between SF and the
current boiler temperature and both green
L
EDs will flash.
8
. To set to maximum rate.
Turn the left hand
k
nob fully cloc
k
wise. As the
k
nob is
turned the display will change, indicating the fan speed.
9. The display will show 00, indicating maximum rate,
then revert to
P
alternating with the current boiler
temperature.
1
0. To set to minimum rate.
Turn the left hand
k
nob fully anti-cloc
k
wise. As the
k
nob is
turned the display will change, indicating the fan speed.
When the display reads 0 the boiler runs at minimum
rate.
11
. This function is maintained for 20 minutes unless the
maximum
C
H temperature is exceeded. The function can
be disabled at any time by turning the right hand
k
nob.