Below is a brief descrip�on:

Charging Times

Using 12V Repair

12V  Repair  is  an  advanced  ba�ery  recovery  mode  for  repairing  and  storing,  old,  idle,  damaged, 

stra�fied or sulfated ba�eries. Not all ba�eries can be recovered.
Ba�eries tend to become damaged if kept at a low charge and/or never given the opportunity to 

receive a full charge. The most common ba�ery problems are ba�ery sulfa�on and stra�fica�on. 

Both ba�ery sulfa�on and stra�fica�on will ar�ficially raise the open circuit voltage of the ba�ery, 

causing the ba�ery toappear fully charged, while providing low capacity. 
Use 12V Repair in a�empt to reverse these problems. For op�mal results, take the 12-volt ba�ery 

through a fullcharge cycle, bringing the ba�ery to full charge, before using this mode.12V Repair can 

take up to four(4) hours to complete the recovery process .

The es�mated �me to charge a ba�ery is shown below. The size of the ba�ery (Ah) and its depth of 

discharge (DOD) greatly affect its charging �me. The charge �me is based on an average depth of 

discharge to a fully charged ba�ery and is for reference purposes only. Actual data may differ due to 

ba�ery condi�ons. The �me to charge a normally discharged ba�ery is based on a 50% DOD.

CAUTION: 

USE THIS MODE WITH CARE. THIS MODE IS FOR 12-VOLT LEAD-ACID BATTERIES ONLY.

THIS MODE USES A HIGH CHARGING VOLTAGE AND MAY CAUSE SOME WATER LOSS IN WET

(FLOODED) CELL BATTERIES. BE ADVISED, SOME BATTERIES AND ELECTRONICS MAY BE SENSITIVE TO 

HIGH  CHARGING  VOLTAGES.  TO  MINIMIZE  RISKS  TO  ELECTRONICS,  DISCONNECT  THE  BATTERY 

BEFORE USING THIS MODE.

It is important to understand the differences and purpose of each charge mode and battery type.Do 

not operate the charger until you confirm the appropriate charge mode and battery type for your 

battery.

1.2-120Ah
14.8V/4A
-4

 

 F - 41

 

 F 

( -20 - 5  C )

-4

 

 F - 41

 

 F 

( -20 - 5  C )

-4

 

 F - 41

 

 F 

( -20 - 5  C )

1.2-120Ah
14.8V/4A

1.2-120Ah
14.8V/4A

1.2-60Ah
14.4V/2A
41  F - 122  F 
( 5 - 50  C )

( 5 - 50  C )

( 5 - 50  C )

( 5 - 50  C )

( 5 - 50  C )

( 5 - 50  C )

( 5 - 50  C )

( 5 - 50  C )

( 5 - 50  C )

( 5 - 50  C )

1.2-60Ah
14.8V/2A
41  F - 122  F 

1.2-60Ah
14.2V/2A
41  F - 122  F 

1.2-120Ah
14.4V/4A
41  F - 122  F 

1.2-120Ah
14.8V/4A
41  F - 122  F 

1.2-120Ah
14.2V/4A
41  F - 122  F 

1.2-120Ah
15.8V/1.5A Max
41  F - 122  F 

1.2-120Ah
15.8V/1.5A Max
41  F - 122  F 

1.2-120Ah
15.8V/1.5A Max
41  F - 122  F 

1.2-60Ah
7.2V/2A
41  F - 122  F 

Ba�ery Size

Approx. Time to Charge In Hours

Ah

20
40
80

100
120

2.9
5.7

11.4
14.3
17.1

2.9
5.7

11.4
14.3
17.1

6V

12V

Reviews: