BRX Power Injector Installation Guide
23
180-0192-001-R01
4
BRX Power Injector Visual Indicators and Troubleshooting Guidelines
The BRX Power Injector incorporates Visual Indicators (or Status LEDs) to provide a quick indication
about the operation of the device. This section incorporates troubleshooting guidelines to assist you
in resolving issues that may arise.
4.1 LED Descriptions
The BRX Power Injector incorporates status LEDs to confirm its proper operation and report any
problems with the loops.
Table 10: Power LED
Table 11: BRX Power Pair Status LED
PAIR LED
Off
No current (DC load), less than 2mA
detected on the pair (no BRX present)
Green
Current (DC load) higher than 2mA but
less than 35mA detected (BRX present)
Amber
Current overload (DC load), over 35mA
detected
Red
Current overload protection activated (Pair
short)
Power LED (main board and modules)
Off
No Power Source
Green
Power Source present
Power LEDs
Pair LEDs