Part 11
not be responsible for any technical support to questions on this aspect.
APPLICATION ENVIRONMENT
It is
very
important that you check the following operational guidelines:
Ventilation
This terminal must
NOT
be operated in an environment with restricted
ventilation. There must be at least 25 mm air clearance around any top or side
ventilation holes with a free flow of air around the unit at
ALL
times for the
installation.
Operating Environment
The equipment must not be operated or stored in extremes of both temperature
and humidity/moisture. (Operating range 0°C to 40°C and up to 80%
humidity – non condensing, max. wet bulb 26
°
C)
POWER ON/OFF
Touch Open Cover
Please refer to the previous chapter
PRODUCT PICTURE
during this part in
order to find out the buttons. A gentle tap on the touch open cover at left side
of the main unit will open the cover and show the power switch at top area. It
is preferable to keep this door closed through daily operation.
There must always be at least 10 seconds waiting before switching on again
once the system is powered off successfully.
Power Indicator
There is a power indicator LED module serving for several purposes under the
logo at center of lower rim of LCD panel. The
relationship between the indicator status and other
conditions is summarized in following table:
Indicator Status
System
Status
External
Power
UPS Battery Powering Up
Off
Off
Off
Not present Not possible
Off
Off
Off
Present
Not allowed
Green
Off
On
No influence
Allowed
Blue
On
On
No influence Not required
Blue/flash
On
Off
Activated
Not required
Green/rapid flash
On
Off
Running at
low capacity
Not required