Find joining points on pole display base 

 
 
 
 
 
 
 
 
 
 
Take PD-2601 out of its box and refer to 

Pix. 3

 that is a picture of the 

pole display base unit (lowest part of the PD) with 2 enlarged portions to the 
right and a slightly enlarged side view picture to the left to find 2 bottom 
locking lugs 

A’

; 2 short cylindrical locating bosses B’ to fit into I/O plate; and 

2 plastic screw bosses 

C’

 on side. Please note that the PD cable comes out of 

the bottom end of the base tube yet in the illustration pictures the cable is 
eliminated for sake of minimum visual confusion. 

Insert bottom locking lugs 

 
 
 
 
 
 
 
 
 
Turn the pole display base unit opposite to have the bottom locking 

lugs 

A’

 in 

Pix. 3

 facing left and now insert the 2 bottom locking lugs 

A’

 on 

base unit into the 2 rectangular installation holes 

A

 on bottom of HT  or PB 

chassis from the right corner with the pole display slightly inclined to the left 
as in 

Pix. 4

. Please note that both bottom locking lugs 

A’

 should be completely 

inserted and come out of the bottom plate of HT or PB system as emphasized 
by an arrow in the enlarged portion. 

Fit in locating bosses 

Please always keep a gentle pressure at the bottom end of pole base 

(bottom locking lugs 

A’

) to the left (away from the sidewall of system chassis) 

when moving the upper part of pole toward sidewall and matching the 2 short 
cylindrical locating bosses 

B’

 into 2 round holes 

B

 in the I/O plate. Please refer 

to 

Pix. 5

 to see the 2 locating bosses 

B’

 from inside of HT or PB system. 

A’ 

A’ 

B’ 

B’ 

C’ C’ 

Pix. 3 

Pix. 4 

A’ 

Summary of Contents for PD-2601 Series

Page 1: ...ing without limitation loss of data or profits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual c...

Page 2: ...less touch POS terminals or TP series touch POS terminals Two line display with 20 characters per line Adequately large characters for easy viewing 9 03 mm by 5 25 mm Long life and trouble free operation 15 30 and 45 adjustable viewing angles Total height 486 or 386 mm PD 2601 on HT and PB series Total height 330 mm PD 2602 on base of KS and TP series Display framecan rotate horizontally270 freely...

Page 3: ...system has to be opened with sufficient precautions First push in the circled knobs on both sides as in Pix 1 to remove the back cover Take out the arrow pointed pole cover from it Opening the top cover of system Prepare a piece of clean soft clothe of appropriate size in front of the HT system to prevent damage Turn the display panel to straight up position For both HT and PB system push in the r...

Page 4: ...cking lugs A in Pix 3 facing left and now insert the 2 bottom locking lugs A on base unit into the 2 rectangular installation holes A on bottom of HT or PB chassis from the right corner with the pole display slightly inclined to the left as in Pix 4 Please note that both bottom locking lugs A should be completely inserted and come out of the bottom plate of HT or PB system as emphasized by an arro...

Page 5: ... chassis Only 1 screw needs to be applied Use the self tapping screw that comes with PD 2601 to fix from external side of sidewall as demonstrated in Pix 6 Connect interface cable Carefully close back the top cover of HT or PB system and connect the interface cable of PD 2601 to appropriate port in system connector area Then close the back cover of the system INSTALLING PD 2602 Opening the rear co...

Page 6: ...ece of plastic cover for the DIP switch window Slide the cover downward but don t pull it off otherwise you may have to practice for inserting it back You can find 6 positions of DIP switches in this window Adjust for the appropriate command mode used by the application program according to below table Switch position counts from left to right and ON means pushed up as indicated in the right part ...

Page 7: ...installed and with COM port power set for serial models turn on the HT or KS or TP Posiflex POS system a firmware identifier as power on sign will appear on the pole display screen for a while to indicate that pole display is self tested O K and ready to work ...

Page 8: ...E SELECTION GUIDE The below table provides some comparison for selection on command mode to be used in the application program if it is not yet determined Mode ADM Aedex Epson Futaba Noritake UTC Cursor N A N A Invisible Blinking Block Blinking Block Blinking Block DP Default mode N A N A Over W V scroll Over W PT User defined font N A N A 2 chars N A 2 chars 2 chars PT Brightness control NO NO YE...

Page 9: ... system 5VDC 1A ENVIRONMENTAL Operating temperature 0 to 40 C Storage temperature 20 to 70 C Operating humidity 20 to 85 non condensing Storage humidity 5 to 90 non condensing WARNING If the user opens the pole display housing to make any modification all the product warranty will be voided NOTE Please refer to Posiflex Product Information CD or visit our web http www posiflex com twfor further in...

Page 10: ...Multi lingual 03 3 PC860 Portuguese 04 4 PC863 Canadian French 05 5 PC865 Nordic 06 6 Russian 07 7 Albic 13 19 PC858 Euro FD 253 PC437G Greek FE 254 Win1257 Windows Baltic FF 255 Win1253 Windows Greek The list of commands available in each mode can be found in the appendix 警告使用者 這是甲類的資訊產品 在居住的環 境中使用時 可能會造成射頻干 擾 在這種情況下 使用者會被要 求採取某些適當的對策 T31454 ...