20.  Auxiliary cable exit 
21.  Rubber feet 

22.  Optional CDROM drive 

PRODUCT FEATURES 

Standard Features: 

a) 

CPU: VIA C7 1.5 GHz or above 

b) 

Fanless structure with Aluminum die cast main unit casing

 

for harsh 

environment 

or metal

 

c) 

Data storage device:  SATA  HDD 3.5”  80 GB in base stand or  IDE 
HDD 2.5” 40 GB in main unit.

 or uDOC

 

d) 

An advanced slim or universal base design. The slim base supports 2

nd

 

LCD display or pole mount customer display on rear base, storage room 
for 3.5” HDD and optional  UPS battery in base. The universal base 
supports extensive features as 2

nd

 LCD display or pole mount customer 

display  on rear base, 3.5” HDD housing, power  adaptor housing, 
optional UPS battery storage in base. Also possible to be without base 
but wall mount bracket for wall mount application. 

e) 

Support WinCE, Win XP Pro, WEPOS,  POS Ready and Linux 
environment 

f) 

High quality 15” TFT active matrix LCD panel. 

g) 

Brightness control by either software or hardware 

h) 

Vertical type LCD panel with easy tilt

 angle adjustment from 15° to 

70° 

i) 

Durable resistive type  (leading edge  Infra  Red type optional)  touch 
panel that endures 35 million touches min. at same spot 

j) 

Spill proof water resistant structure allowing easy cleaning 

k) 

Easy maintenance construction 

l) 

Various I/O ports supported, including: 
1.  one PS/2 KB port (inside touch-open cover) 
2.  4 serial ports with capability for +5V DC support in form of 10 pin 

RJ45 jacks 

3.  one parallel port 
4.  4 standard USB ports 
5.  one proprietary USB port for optional side mount kit (e.g. SD-400) 
6.  one LAN port 10/100 base T Ethernet 
7.  one external VGA monitor port 
8.  one 4 pin lock type DC 12 V power input connector 
9.  one UPS battery connector 
10. one “EXT PWR” port for power supply to SATA device 
11. 2 SATA ports for Serial ATA HDD in base or external device 

Summary of Contents for KS - 6215N

Page 1: ...esulting from the furnishing performance or use of this material This information is provided as is and Posiflex Technologies Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essential hardware con...

Page 2: ...improper maintenance reduces the battery life dramatically Always fully recharge the battery at least once every 3 months if the battery is not connected Always disconnect the UPS battery from the system if the system is to be left OFF for more than 72 hours to prevent possible damage Only connect the UPS battery back right before you are going to re power on the system Replace the battery as soon...

Page 3: ...NTRODUCTION PRODUCT PICTURES Front Views Side Views 1 1 11 12 Slim base Universal Base 10 10 9 9 6 5 Slim base 13 14 15 6 1 Slim base 6 3 4 1 1 Universal Base Slim base Universal Base 4 5 6 8 7 7 8 9 9 6 5 2 2 ...

Page 4: ... Removal hollow in cable cover 9 Lock release lever for tilt angle adjust 10 Lock release button for main unit detach 11 Touch open cover 12 Power switch 13 Brightness adjust thumb wheel 14 Touch open door latch 15 PS 2 KB port 16 Rear connect cover 17 Power connector hole 18 Cable exit 19 2nd Cable exit 18 Universal Base 21 Slim base 18 19 20 21 1 1 Slim base Universal Base 7 7 6 5 18 18 16 16 17...

Page 5: ...port WinCE Win XP Pro WEPOS POS Ready and Linux environment f High quality 15 TFT active matrix LCD panel g Brightness control by either software or hardware h Vertical type LCD panel with easy tilt angle adjustment from 15 to 70 i Durable resistive type leading edge Infra Red type optional touch panel that endures 35 million touches min at same spot j Spill proof water resistant structure allowin...

Page 6: ...t MODEM ring or LAN Option Items Note The underlined items in the following list means that option must be set prior to shipment from the factory The rest items can be set by the dealers a DDR2 SDRAM memory expansion up to 1GB b RS232 interface Infra Red type touch panel durable for 50 million touches min at same spot c 2 HDD installation or uDOC d Integrated side mount upgrade kit SD400 MSR finge...

Page 7: ...ible then Please first note orientations of every existing cable connection and then disconnect every cable properly before separating the main unit from the adjustable stand assembly Please note that the click lock spring has to be pressed down prior to pulling out the connector such as the LAN port Please also note that the fixing screws have to be loosened free prior to disconnection such as th...

Page 8: ...om plate up and the inside of an example slim base model looks like this in the above right picture The inside of an example universal base model will look like the picture on next page Both with numbered items listed on next page However there could be some variation to the contents inside depending on what option items actually installed Step A Prepare a soft clean flat surface such as a piece o...

Page 9: ...through the 2 standing slits on base box to fix the battery in position firmly Route the battery connection cable through appropriate passage to the battery connector on the main unit Please remove the UPS battery bracket fixing screw and slide right the UPS battery bracket to take it out for universal base model as in left picture Put the battery in at the other end first and remount the bracket ...

Page 10: ...or illustration purpose only Please push the plastic hook plate with finger through the top opening in the stand assembly to remove the rear connect cover 12 2nd LCD Panel Or Customer Display Fit the joint base of PD 2501 or PD 2602 or LM 6101 to the rear connect cover opening Please route the interface cable through the normal cable exit under the joint base as in the 2 pictures Fit 2 screws thro...

Page 11: ...ort and COM port power supply function Please consult your dealer for technical support on setup of these jumpers Please note that only those qualified technicians may adjust in the service window with information from Posiflex and the contents in the service window may change without notice as time develops SIDE MOUNT UPGRADE KIT Remove the 2 circled screws in last picture above to remove the cov...

Page 12: ...ed type touch panel is used KS 6115U 294 5 391 5 WALL MOUNTING The wall mount model is delivered without any base but with a wall mount kit Please follow the installation guide that comes with the wall mount bracket to fix the wall mount bracket on wall and then hang the main unit with the matching pegs into the matching holes on wall mount bracket Please note that since there is no base for the w...

Page 13: ... care of software restoration after OS recovered A Posiflex supplied USB interface CDROM drive will be required for such action Other brand CDROM drive may require its specific driver different from what supported in the recovery CD Should there be any difficulty in using the Posiflex supplied USB interface CDROM drive in recovery please try disable the USB 2 0 function of system BIOS setup by goi...

Page 14: ...Part 14 Inc shall not be responsible for any technical support to questions arisen due to non preloaded OS ...

Page 15: ... hours every month for temperature over 30 C Temperature above 40 C must be strictly avoided as it could cause termination of battery life and unexpected result even if the battery is not in work The UPS battery can support basically the data preservation and smooth running of the system during intermittent or few minutes 15 30 min depending on loading and battery condition power failure Battery r...

Page 16: ... power outlet and any power fusing arrangements must conform to local safety regulations Please never do any connection disconnection when system is still powered on Please always keep the external power adaptor in a free air circulation POWER ON OFF Touch Open Cover A gentle tap on the touch open cover at left side of the main unit will open the cover and show the power switch thumb wheel knob fo...

Page 17: ...re registers may be confused causing trouble for system restart or even this forced power off please disconnect the UPS battery if installed and the AC power supply for few minutes This may allow all hardware registers to reset This switch can also be programmed as an ON only switch That means if the application program issues a command compliant with the KS series technical manual this switch wil...

Page 18: ...et Please note that if the KS system is improperly turned off before a complete boot up procedure the above preset power on control functions will be disabled until next turning off after a complete boot up DISPLAY ISSUES Main LCD Display For best viewing result please set your display resolution at 1024 x 768 with 16 2 M colors In configuration of system memory max 64 MB can be shared as the vide...

Page 19: ...rner of the main unit but no direct access port in the main unit The external access to audio ports can be found in the side mount option kit like SD 400 with a Microphone in and a stereo line out jacks at its bottom surface as circled in the right picture The internal speaker will be automatically disconnected when a plug is inserted in the line output jack HDD SATA PORTS The 2 5 HDD if installed...

Page 20: ...f the mouse To obtain the effect like clicking on the right button of a mouse touching any point on the screen surface after touching the right click sticky button results as a click on the right button of the mouse at that point Posiflex USB Touch Manager A program named Posiflex USB Touch Manager and a right click sticky button tool in the program group Posiflex USB Touch Tools is installed in t...