Posh POS 708 User Manual Download Page 7

POS 708 USER MANUAL Ver. 1.6 

 

CONTENT INCLUDED: 

1.

 

Pos 708 Device

 

2.

 

1 Black Velcro double-sided adhesive strip.

 

3.

 

Manual.

 

 
WARRANTY: 

1-year limited warranty for parts and Labor. Warranty is void if anyone other then the Manufacture’s repair 
department or an authorized repair center services the POS708.  
 

Table 6: Technical Specifications 

 

 
POS 708

 

POS708-USB: Virtual Serial HID Port 

POS708-RS232: Communication set to: 9600 Baud, 8 Data bits, No Parity, 1 Stop bit 

Selectable modes 
using Dip Switches

 

Cash Drawer Alarm (Until Drawer is closed) 
Cash Drawer Alarm (Until Drawer is closed or Max 1 Min. On)  

Paper Sensor Alarm (Until receipt is removed)          Paper Sensor Alarm (Until receipt is 
removed or Max 1 Min On) 

Power 

 

USB provides 5V power on USB Version,  24Vdc Power Adaptor  powers Drawer & Buzzer 
on both. Only on the RS232 Version the  24Vdc Adaptor also provides 5V to the POS708 
RS232. 

Current 

45 - 100 mA typical current used by POS708 device only (Cash Drawers may require up to 
1000 mA provided by 24Vdc Adaptor.) 

 Drawer 
Connectors

 

2 x RJ12 , Drawer 1 & Drawer 2 

Dimensions

 

80 x 45 x 28.5 mm (WxDxH) 150 gm 

 USB / RS232 
Cable Lengths

 

180 cm (6 Feet)  Max distance can be up to 15 Feet for USB only.  RS232 DB9F cable is (6 
Feet) max 100 FT cable for RS232 

Humidity / Temp.

  10% - 90% relative humidity , -20C  to 55C 

Drawers  
Supported 

 

Star/ Epson/ Citizen/ IBM and compatible cash drawers  with RJ12 connection N/O 
(Normally Open) Drawer Switch only 

Piezo Electric 
Buzzer 

 

4.5 kHz  @ 90 dBA at 30 cm, External Buzzer connection option 

Drawer Triggers

 

The Drawers are triggered by sending the trigger characters to the VRS or RS232 port that 
the POS708 is connected to. Drawer 1 is triggered by CHR(7) and Drawer 2 is triggered by 
CHR(19). 

Drawer Alarm 

Alarm will sound if either drawers are left opened pass the wait time set by SW 2/3 Cash 
Drawer must have an RJ12 cable with a drawer normally open switch (N/O) for the Drawer 
Alarm to function.  

Push Button Test 

The POS708 has a push button on top which allows you to test the Buzzer and LED. All 
drawers must be closed for this function to work.  The Push Button does not have any affect 
the normal operations of the POS708.  

Operating System 

Not dependent on any operating system or software 

Warranty

 

1 year  

Summary of Contents for POS 708

Page 1: ...POS 708 USER MANUAL Ver 1 6 1 POS 708 Dual Cash Drawer Alarm USB RS232 ...

Page 2: ...ired to support a drawer open switch The drawer open switch should be N O Normally Open when the cash drawer is closed The POS708 can only support N O cash drawers DO NOT MIX Drawer Switch types You can use up to TWO N O drawer s on the POS708 See Figure 5 6 for typical cash drawer wiring requirements The cash drawer alarm features of the POS708 do not need any software changes to your application...

Page 3: ...d other service industries NO software changes are needed with the POS708 and Psen combination If you are using a POS708 with Ver 1 1 or Ver 1 3 PCB you will require a special 708 PSen designed for these PCB Features of the POS708 include a dual RJ12 female connector status LED 24 Vdc external power supply Included with POS708 and an alarm that is switch selectable The POS 708 has no internal jump...

Page 4: ...hen any drawer is open before sounding Alarm See Table 1 Sw4 ON Alarm Speaker Eenabled Sw4 OFF Alarm Speaker Disabled Alarm Option A Sw1 ON Alarm will sound when drawer is open for XX seconds then turn off Alarm after 60 seconds or close all drawers Alarm Option B Sw1 OFF Alarm will sound when drawer is open for XX seconds Close drawer to turn off Alarm Table 1 POS708 Dip Switch 2 3 POS 708 RS232 ...

Page 5: ...re 7 Typical Star Cash Drawer Wiring Pin Number Drawer 1 Signal Name Drawer 2 Signal Name Direction 1 Frame Ground Frame Ground Ground 2 Drawer 1 Sink Signal Drawer 2 Sink Signal Input 3 24 VDC 24 VDC Power 4 24 VDC 24 VDC Power 5 Drawer 2 Sink Signal Drawer 1 Sink Signal Input ...

Page 6: ...daptor supplied also provides the 5V power on the RS232 version only A flashing LED indicates that an event is active Drawer is Open or in a Timing Loop INSTALLATION Select Cash Drawer Aalarm On state using Dip switches 1 60 seconds or Stay on until all drawers are closed Select Time duration for the Selected Option Dip switches 2 3 Wait time when any drawer is open before sounding Alarm Connect C...

Page 7: ...er Connectors 2 x RJ12 Drawer 1 Drawer 2 Dimensions 80 x 45 x 28 5 mm WxDxH 150 gm USB RS232 Cable Lengths 180 cm 6 Feet Max distance can be up to 15 Feet for USB only RS232 DB9F cable is 6 Feet max 100 FT cable for RS232 Humidity Temp 10 90 relative humidity 20C to 55C Drawers Supported Star Epson Citizen IBM and compatible cash drawers with RJ12 connection N O Normally Open Drawer Switch only Pi...

Page 8: ...akes no claims or warranties with respect to the content or accuracy of this publication or the product it describes including warranties of fitness or merchantability for a particular purpose The Manufacturer shall not be liable for any special incidental or consequential damages nor damages due to use or misuse born from integration into any mechanical electrical or computer system The Manufactu...

Reviews: