background image

3

Customer Support

Many of the steps in this guide have corresponding how-to 

videos. View them on the Poseidon Flow Technologies web-

site at 

poseidon

fl

 ow.com/support-videos

United States and Canada

Contact Poseidon Flow Technologies Directly for all warranty 

service and returns. Visit 

poseidon

fl

 ow.com/support

International 

Contact your local distributor directly for all warranty service 

and returns. Visit 

poseidon

fl

 ow.com/retailers

Customer Support

Should you require customer support for your Salinity 

Pen Plus

+

, help is o

 ered in the following ways:

Via Phone:

M-F 8:00AM to 5:00PM EST 1-800-202-FLOW

Via support@poseidon

fl

 ow.com

http://poseidon

fl

 ow.com/support

International Support: 

Contact your local distributor directly for all warranty issues 

or returns. Visit 

poseidon

fl

 ow.com/retailers 

to 

fi

 nd the 

contact information for your Poseidon Flow Distributor.

Summary of Contents for Salinity Pen Plus+

Page 1: ...User Guide...

Page 2: ...een The SP can also be easily calibrated in seconds using the included Salinity Standard Solution 30ppt This device has been factory tested to provide trouble free performance and contains certified c...

Page 3: ...ct your local distributor directly for all warranty service and returns Visit poseidonflow com retailers Customer Support Should you require customer support for your Salinity Pen Plus help is o ered...

Page 4: ...2 Button Batteries Included MODE Button Navigate between operational modes Temperature Celsius Fahrenheit Salinity PPT and Specific Gravity SG CAL HOLD Button Allows measurements to be locked on the d...

Page 5: ...tinum sensor Clean only using a damp cloth or sponge with a neutral detergent DO NOT use chemicals such as acetone or benzene to clean any part of the instrument Avoid storing the instrument in places...

Page 6: ...er it is good practice to calibrate your Salinity Pen Plus before use Calibration Procedure Step 1 Turn on the Salinity Pen Plus by depressing the POWER button Step 2 Press the Mode button until the d...

Page 7: ...7 Correct Proper Salinity Pen Plus Usage Notice Measurement Keep the sensor at least 0 5 1cm away from all edges of the container when measuring Incorrect...

Page 8: ...r 3 seconds until the unit change is observed on the display b Press the MODE button to toggle between testing modes Salinity ppt Specific Gravity SG and tem perature Celsius Fahrenheit 3 Immerse the...

Page 9: ...with fresh water ensure to fully dry the sensor using a clean dry cloth or sponge Always keep the sensor dry when not in use WARNING Air bubbles stuck to the sensor after it is immersed into the wate...

Page 10: ...chase receipt POSEIDON FLOW TECHNOLOGIES DISCLAIMS ALL OTHER WARRANTIES WHETHER ORAL OR WRITTEN EXPRESS OR IMPLIED TO THE FULLEST EXTENT ALLOWED BY APPLICABLE LAW NO IMPLIED WARRANTY OF FITNESS FOR A...

Page 11: ......

Reviews: