2.5 Alignment of the seal
1.
To arrange this a the seal is equipped with 4 measure points. To take the
measurements you need to use a Vernier caliper.
2.
Using a wooden or copper hammer you can adjust the seal towards the correct
alignment. All 4 readings should become within 0.2 mm
3.
When the (re)alignment is finished the M16 mounting bolts can be tightened per table
page 8
On the next page the readings can be recorded and/or compared with earlier readings
In the same table each shaft can be recorded.