Troubleshooting
ROBO-8713 Series User’s Manual
5-3
Step 4: Connect TOGGLE SWITCH with J18 connector on ROBO-8713 series (Figure
5-4), which is used to power on ATX Power Supply. Generally, the TOGGLE
SWITCH is located on the chassis of front panel.
Figure 5-4
AT Power Setting
This section will introduce you how to quickly and appropriately set up AT power
on your system.
Step 1: Please adjust AT/ATX Jumper on JP7 to short 1-3, 2-4 pins, then it can
support AT power scheme. (Figure 5-5)
Figure 5-4
Note:
If you currently used ATX mode, please clean CMOS first before adjusting Power
setting to AT mode. Otherwise, system would not boot up properly.