background image

Before starting installation of the external blind, please read the following instructions

.

During transportation and storage, the blind should lie horizontally in a place protected from damage 

to the entire structure.  The blind should not be placed on the side wall. Any modifications 

or changes to the design of the external blind can only be made after consultation with the manufacturer.

Blinds should be installed on an even surface

.

Installation of external blinds should be conducted by persons competent in the area 

of   compliance with health and safety rules and applicable building regulations. 

In the case of external blinds operated with an electric drive, the installation can only be carried out by a person 

with appropriate permissions (SEP rights up to 1 kV)

.  

Directly before installation, unpack the blind and check if there are all elements necessary 

for its installation

.

1. 

Tools needed to install the external blind. The PORTOS company does not provide screws, dowels, cables for placing 

   

the electrical installation

.

2.

 

In the case of dimensioning, the smallest dimension taken, is the right dimension

.

Dimensioning - ZF3000 external blind
aluminium guides, installation in the window recess

Dimensioning - ZF3000 external blind
aluminium guides, 
installation on the facade/ flush-mounted installation

Sz = So

Wz

 = 

W

o

 

EXPLANATIONS TO DIMENSIONING

:

Sz

 - blind width

,  So

 - hole width

,  Wz

 - blind height

,  

Wo

 - 

height of the hole together with the box height

Sz = So*,  Wz = Wo

So

W

o

 

Wz

 

Ws

 

P

P

EXPLANATIONS TO DIMENSIONING

:

Sz

 - blind width

,  So

 - hole width 

Wz

 - blind height

,  Wo

 - hole height

,  Ws

 - box height

P  

  - 

guide width (27mm)

Wz = Wo + Ws

Installation on the facade

:

 Sz = So + 2 x P

Flush-mounted installation

Sz = 

window width

*

ø 6,10,12

INSTALLATION WITH GUIDES

* - 

It is recommended to take into account the installation clearance for free processing of wood elements

.

NOTE

  - 

In the case of installation in the window recess, make sure the recess width and height are equal in all points.

              

If they are different, assume the dimension of the minimum or make a proper correction of the hole

3

INSTALLATION OF ZF3000

-BX

 EXTERNAL BLINDS

Summary of Contents for ZF3000-BX

Page 1: ...R INSTRUCTIONS FOR INSTALLATION AND OPERATION OF THE EXTERNAL BLIND ZF3000 BX ...

Page 2: ... BX BLIND INSTALLATION TYPES A INSTALLATION TYPE flush mounted C INSTALLATION TYPE on the facade box 250 B INSTALLATION TYPE flush mounted with a spacer D INSTALLATION TYPE on the facade with a spacer box 250 ...

Page 3: ... company does not provide screws dowels cables for placing the electrical installation 2 In the case of dimensioning the smallest dimension taken is the right dimension Dimensioning ZF3000 external blind aluminium guides installation in the window recess Dimensioning ZF3000 external blind aluminium guides installation on the facade flush mounted installation Sz So Wz Wo EXPLANATIONS TO DIMENSIONING...

Page 4: ...ersion of the blind with a mosquito net fasten the mosquito net guides as shown in the figure above with 4 2x13 screws mounted every 50 cm 5 Fasten the guides to the window frame with appropriate screws minimum three per side The PORTOS company offers guide drilling free of charge 4 Prepare the guides screw the bottom plugs to the guides using 3x16 screws Break out a part of the side wall in the p...

Page 5: ...ning the inspection cover 5 INSTALLATION OF ZF3000 BX EXTERNAL BLINDS 10 Drill holes for mounting pins in the rear part of the box 11 Screw the box to the wall with appropriate mounting pins 11a Drill holes for mounting pins through the brackets then screw them to the wall BOX ANCHORING 250 INSTALLATION ON THE FACADE BOX ANCHORING FLUSH MOUNTED INSTALLATION 10a Apply the mounting brackets 1 to the...

Page 6: ...e insert the crank pin into the wall 1 into the previously prepared hole as shown in Figure 2 Mark the drilling places for the dowels on the wall Remove the mechanism then drill holes for the dowels 2 1 6 INSTALLATION OF ZF3000 BX EXTERNAL BLINDS 19 View of the properly installed guides with guide inserts 18 Put the guide insert into the guides from the bottom 17 Close the top rail handles and tig...

Page 7: ...25 View of the ZF3000 BX external blind installed 24 After screwing the guides insert the covering end caps into the holes ...

Page 8: ... remote in the case of a switch release the key or press the key with the opposite direction When the blind is fully open or closed the motor will be automatically stopped by the limit switch Use the scroll wheel on the remote for precise setting the position of the external blind slats In case of noticing that the blind curtain has stopped and the motor is still running stop the motor immediately...

Page 9: ...ct The blind should be cleaned with a soft cloth using generally available cleaning agents The use of pressure washers strong cleaning agents and solvents is forbidden When cleaning the product it is absolutely not advisable to use sharp tools and cleaning agents that cause scratches In the case of cleaning the product it is unconditionally necessary to prevent the possibility of water getting int...

Page 10: ...IONS IS IMPORTANT FOR THE SAFETY OF PERSONS KEEP THESE INSTRUCTIONS 11 PORTOS TR7 spółka z ograniczoną odpowiedzialnością s k PN EN 13659 All of the certificates of the useful properties are available on the website www portos company ...

Reviews: