2
EEPROM and will not be lost even if the power is failure.
Note that the device ID, GPRS APN name, GPRS login name and password need to be set
in initial PC setup in order to make the connection to the server. All the reports
configuration or Geo-fence setup can be changed at anytime via over the air commands.
The automatic reporting mode can be categorized as ‘time’ report, ‘distance’ report, or
‘time & velocity’ report. User can choose the reporting mode and related parameters via the
PC setup program or the remote sever.
The event trigger report is also configurable. User can turn on or off any event-generated
report from the PC setup program or via the air command. The event-triggered report
include (1) In-vehicle Door close/open (2) In-vehicle ignition on/off (3) Temperature range
in/out the preset range.
The server cannot only configure the device just like the PC setup program does, but it also
can send the command to control the device. The server can control both the device and the
build in alarm.
1.3
G
EO
-
FENCE FUNCTION
The device has built-in 30 Geo-fence sets (1 immediate Geo-fence, 4 circular, 5 rectangular
and 20 point); it will send the report to the server if the Geo-fence event is triggered. User
can setup the Geo-fence area from the PC setup program or sending the defined.
A unique immediate Geo-fence function:
‘Immediate-Geo-fence function’ is a circular type Geo-fence that can be activated or
deactivated from a single button. When activated, the system will record the current
position and use the pre-defined radius as a circular Geo-fence to guard the vehicle. If the
vehicle moves out of the preset Geo-fence zone, a report will be generated to the server.
User can deactivate the self-Geo-fence at any time by pressing the valet switch again. If the
GPS cannot be located when the Immediate Geo-fence function is been executed,
GT3000X4 will use the last known position as the origin of the circular Geo-fence zone to
perform the protection.
1.4
S
TORE AND FORWARD ABILITY
When there is no GPRS service or the server close. The unit will send short message to the