 READ AND SAVE THESE INSTRUCTIONS.

 

         DANGER

• For your protection and safety, carefully read and understand the information provided 

in this manual  

   completely before attempting to assemble, install or operate this product. Failure to do so could lead  
   to electrical shock, fire or other injuries that could be hazardous or even fatal.

 •  

If using this light fixture in a WET or DAMP location, this light fixture must be connected to a supply  

   circuit that is protected by a Ground Fault Circuit Interrupter (GFCI) to reduce the risk of personal  
   injury, electrical shock or death.

• 

DO NOT connect this fixture to an electrical system that does not provide a means for equipment 

  grounding. Never use a fixture in a two-wire system that is not grounded. Installing a fixture into an 
  electrical system not having a proper grounding means could cause metal parts of the fixture to carry 
  electrical currents if any of the fixture wires, wire connections or splices were to become broken, cut  
  or loose during the mounting or normal operation of the fixture. Under this condition, anyone coming 
   in contact with the fixture would be subject to electrical shock, which could cause serious injury or  
  death.

  

 • 

DO NOT connect the bare or green insulation fixture ground wire to the black (HOT) current-carrying 

  wire or the white (NEUTRAL) house wire. Connection of the bare or green fixture ground wire to the
  black or white house wires may cause metal parts of the fixture to carry electrical currents. Under this  
   condition, anyone coming in contact with the fixture will receive electrical shock, which could cause     
   serious injury or death.

• 

DO NOT damage or cut the wire insulation (covering) during installation of fixture. DO NOT permit     

   wires to contact any surface having a sharp edge. To do so may damage or cut the wire insulation,     
   which could cause serious injury or death from electrical shock.

       

 

         

        WARNING

 

• 

All electrical connections must be in agreement with local codes and ordinances, the National

   Electric Code (NEC) and ANSI/NFPA 70-1999. Contact your municipal building department to learn    
   about your local codes, permits and/or inspections. 

• To avoid personal injury, the use of gloves may be necessary while handling fixture parts with sharp 
  edges.
• 

DO NOT suspend any fixture by the house wires. A fixture must always be mounted directly to a

  mounting plate that is first attached to the outlet box. All fixtures must be mounted to an outlet box that
  is supported by the building structure. Wire connectors will not support the weight of a fixture.
  Suspending a fixture by the house wires and wire connectors will result in the fixture falling, with the
  possibility of personal injury and the danger of electrical shock or fire.

• 

To reduce the risk of fire, electrical shock or personal injury, wire connectors provided with this 

light 

  fixture are designed to accept only one 12-gauge house wire and two lead wires from the light fixture. 
  If your house wire is larger than 12-gauge or there is more than one house wire to connect to the  
  corresponding fixture lead wires, consult an electrician for the proper size wire connectors to use.
• To avoid water damage to fixture or possible electrical malfunction, install fixture at least 4 ft. above 
  the ground/floor.
• Failure to caulk fixture mounting surface with silicone weather sealant may result in water damage   
  in outlet box, which may cause electrical malfunction or electrical shock. 

SAFETY INFORMATION

Lowes.com/portfolio

Summary of Contents for 0398473

Page 1: ...ial Number Purchase Date 1 Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 643 0067 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday Portfolio is a registered trademark of LF LLC All Rights Reserved Lowes com portfolio EB1596 For Wet Location ...

Page 2: ... Qty 2 G F B C E BB AA Lowes com portfolio H Housing Screw 1 preassembled to Housing Cover E A Fixture 1 C Housing 1 B Mounting Plate 1 PART DESCRIPTION QUANTITY D Panel 4 E Housing Cover 1 F Cap 1 G Bottom Finial 1 CC DD Top Finial Qty 1 Top Finial Screw preassembled to Top Finial CC Qty 1 H D ...

Page 3: ...age or cut the wire insulation covering during installation of fixture DO NOT permit wires to contact any surface having a sharp edge To do so may damage or cut the wire insulation which could cause serious injury or death from electrical shock WARNING All electrical connections must be in agreement with local codes and ordinances the National Electric Code NEC and ANSI NFPA 70 1999 Contact your m...

Page 4: ...EPARATION CAUTION TURN OFF ELECTRICITY at main fuse box or circuit breaker box before beginning installation by removing the fuse or switching the circuit breaker off If you are not sure the lighting system has a grounding means DO NOT attempt to install this fixture Contact a qualified licensed electrician for information regarding the proper grounding methods as required by the local electrical ...

Page 5: ...ounting plate B so fixture screws are parallel with floor and ceiling Tighten outlet box screws to secure mounting plate B Make sure the outlet box can support 35 lbs hanging weight Use metal outlet box plastic outlet boxes are not recommended 2 3 4 4 Attach bottom finial G to bottom of fixture A Align small gap in opening at bottom of housing C with small tab on socket cover of fixture A and pres...

Page 6: ...es from the light fixture If your house wire is larger than 12 gauge or there is more than one house wire to connect to the corresponding fixture lead wires consult an electrician for the proper size wire connectors to use x 3 Insert panels D beveled side out into each slot on inside of housing C Tip When inserting last panel D slide the panel D down as far as possible on one side Then while press...

Page 7: ...ector AA down to the wire WARNING Make sure no bare wire or wire strands are visible after making connections Carefully arrange excess wiring and wire connectors AA within outlet box 6 9 9 A 8 x 2 Hardware Used Decorative Screw Install one standard base bulb not included Use either a 60 watt max incandescent or a 13 watt CFL IMPORTANT When replacing bulb please allow bulb and fixture A to cool dow...

Page 8: ...H fits in keyhole slot in top edge of housing C 10 10 Remove top finial screw DD from top finial CC Locate hole at top of housing cover E and insert top finial screw DD through hole from underside of housing cover E Align hole in cap F with top finial screw DD Secure with top finial CC NOTE Make sure to align cap F with housing cover E after tightening top finial CC 11 CC DD x 1 Hardware Used Top ...

Page 9: ...uded WARNING Failure to caulk fixture mounting surface with silicone weather sealant may result in water damage in outlet box which may cause electrical malfunction or electrical shock Lowes com portfolio 6 13 Restore power and test fixture A If light does not function please refer to TROUBLESHOOTING on the next page 12 6 12 A A ...

Page 10: ...n and specifically excludes liability for direct incidental or consequential damages improper packaging of returned products and acts of God As some states do not allow exclusions of limitations on an implied warranty the above exclusion and limitation may not apply This warranty gives you specific rights and you may also have other rights which may vary from state to state WARRANTY TROUBLESHOOTIN...