3.  Install each control receiver (1) on the corresponding numbered backstop or gymnasium divider support structure as shown on 

installation print, within 3'-0" of the electric winch that it is to control.  Use the cable ties (4) provided to attach enclosure
mounting strap to 3-1/2" O.D. superstructure pipe as shown below.  Two (2) #10 screws (not provided) may be used to attach to 
wood or other type framing structures if necessary. 

TYPICAL 3½” O.D. 

SUPERSTRUCTURE ATTACHMENT 

12002-100 

TRANSMITTER

 

After receiver is mounted, double-check to ensure that the control box number corresponds to the number marked on the 
equipment (1 to 1, 2 to 2, etc.). 

4.  Plug 4-prong twist-lock plug from electric winch into control receiver box (1).  Plug 3-prong twist-lock power cord from the

control receiver box into the power source (115 volt, single phase, 60 cycle), using the 3-prong twist-lock receptacle (2) and 1/2" 
deep cover plate (3) provided. 

5.  With the basketball backstop or gymnasium divider curtain in the down position, test the operation of the unit with the No. 12002-

100 portable transmitter control unit. 

 

CAUTION! – Always keep hands away from the V-belts and pulleys when operating unit. 

 

A.  Set selector display (1 thru 99) to position 1 by pressing the next button.  The numeric LED will illuminate displaying the

address “01” (see illustration above). 

 

B.  Press “RAISE” button - backstop or gym divider curtain marked No. 1 should begin up cycle. 

 

C.  Set rotary counting limit switches per winch installation instructions. 

 

D.  Repeat steps A thru C for all units. 

6.  All units must be tested through a complete up/down cycle before leaving the jobsite, to ensure proper operation with the portable

transmitter control unit AND limit switch settings. 

7.  If the transmitter does not activate one or more of the winch units, double-check the coding switch settings. 

8.  If the receiver is in the proximity of a metal beam or other obstruction, it may be necessary to relocate the receiver to increase the 

operating range. 

9.  Should intermittent operation develop: 
 

A.  Stand closer to the basketball backstop or gym divider curtain receiver unit. 

 

B.  Replace the battery in the portable transmitter control unit (standard 9-volt alkaline battery). 

10.  Place the portable transmitter control unit(s) 

and this I

NSTALLATION 

& O

PERATION 

M

ANUAL

 in the possession of an authorized 

staff member from the electrical contractor, general contractor, or the school, and demonstrate the operation of the system. 

Summary of Contents for 12002 Sportsonic II

Page 1: ...OTE CONTROL SYSTEM FOR BASKETBALL BACKSTOPS GYMNASIUM DIVIDERS ETC No 12002 Sportsonic II INST 00358 042 2015 PORTER ATHLETIC INC ALL RIGHTS RESERVED 11 6 2015 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE AND TO ORDER REPLACEMENT PARTS ...

Page 2: ...2 ...

Page 3: ...y Enclosure shall be furnished with a 4 pole twist lock grounded type NEMA L14 20 receptacle to accept the power control cable from the electric winch Receiver shall allow for dual control of equipment Sportsonic II or key switch Each radio controlled receiver shall include an external 3 screw terminal strip for optional low voltage key switch type control The terminal strip shall allow for connec...

Page 4: ...4 ...

Page 5: ...rs for power supply Enclosure shall be furnished with a 4 pole twist lock grounded type NEMA L14 20 receptacle to accept the power control cable from the electric winch Receiver shall allow for dual control of equipment Sportsonic II or key switch Each radio controlled receiver shall include an external 3 screw terminal strip for optional low voltage key switch type control The terminal strip shal...

Page 6: ...portsonic II receiver enclosure rotate small cover up to expose DIP switch window Locate receiver DIP switch module inside enclosure window small black plastic module with white slide tabs numbered 1 thru 7 Set the receiving code module on each receiver per the following chart As each box is set and DIP switch cover closed write the operating identification number 1 thru 99 on the outside of the b...

Page 7: ...m the V belts and pulleys when operating unit A Set selector display 1 thru 99 to position 1 by pressing the next button The numeric LED will illuminate displaying the address 01 see illustration above B Press RAISE button backstop or gym divider curtain marked No 1 should begin up cycle C Set rotary counting limit switches per winch installation instructions D Repeat steps A thru C for all units ...

Page 8: ... connection of low voltage dry circuit type 5 volt maximum key switch wires up down and common Refer to the diagram below for wiring details Note Do not connect high voltage key switch wires to the receiver terminals Introduction of powered key switch wires at the terminal strip will permanently damage the receiver CAUTION WIRING AT WALL MOUNTED KEY SWITCH WIRING AT RECEIVER POWER SOURCE JUNCTION ...

Page 9: ...se 12002 100 TRANSMITTER Stand within 50 feet of unit number 1 To raise the unit press the RAISE button and hold during the up cycle until the limit switch stops the unit To lower the unit press the LOWER button and hold during the down cycle until the limit switch stops the unit To stop the operation of the unit release the button To reverse the operation of the unit allow the unit to come to a c...

Page 10: ...y proof of purchase If service is required under this warranty 1 Call or write to Porter Athletic Inc for a Return Merchandise Authorization number to be affixed to returned packaging This RMA number will also be your reference number 2 Return defective unit postage or freight prepaid to Porter Athletic Inc 601 Mercury Drive Champagin Illinois 61822 3 Enclose dated proof of purchase 4 Enclose chec...

Page 11: ...11 THE OWNER OF THIS EQUIPMENT MUST SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE AND TO ORDER REPLACEMENT PARTS ...

Page 12: ...m 888 277 7778 THIS WARNING IS GIVEN IN COMPLIANCE WITH CALIFORNIA S PROPOSITION 65 WARNING This product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm WARNING Cancer and Reproductive Harm For more information go to www p65warnings ca gov F ...

Reviews: