background image

5 - ENG

USER-MAINTENANCE INSTRUCTIONS

TROUBLESHOOTING GUIDE

TOOL SPECIFICATIONS

Maximum Torque

50 ft/lbs

Average SCFM Requirements

4.0 SCFM @ 90 PSI

Air Inlet

1/4” NPT (female)

Square Drive

3/8”

Recommended Hose Size

3/8”

Maximum Working Pressure

90 PSI

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Tool will not run or runs 
slowly

Grit in tool; tool gummed up

Clean the air motor inside the tool with 
WD-40® (see “user maintenance” section).

No oil in tool

Add 4-6 drops of air tool oil into the air inlet of 
the tool (see “user maintenance” section).

Low air pressure

Adjust compressor regulator to 90 PSI.

Air hose leaks

Tighten and seal hose fittings with Teflon® tape 
if leaks are found.

FREE WARNING LABEL REPLACEMENT:

 If your warning labels become illegible or are missing, call 1-(888)-

895-4549 for a free replacement.

Air Motor Lubrication

  To maintain the maximum performance of the air tool, it must be lubricated each time it is used. Dust, dirt, 
rust and oil residue will build up inside the tool and reduce the performance. An in-line oiler is recommended for 
proper automatic tool lubrication (see Figure A). If an in-line oiler is not available, the tool can be lubricated manu-
ally through the inlet port (see Figure C).

1.  Disconnect the air tool from the air supply.

2.  Turn the tool upside down and while depressing the trigger, add 4-6 drops    

Air tool oil

Male plug

Air inlet port

C

  

  of air tool oil or SAE10 nondetergent oil into the air inlet. 

NOTE:

    

  Depressing the trigger helps circulate oil in the air motor. 

3.  Reconnect the tool to the air supply, cover the exhaust port end with a  
  towel and run in forward and reverse directions for approximately 30  
  seconds to remove excess oil.
 

NOTE: If the tool remains sluggish after it has been lubricated, the  

  internal components may need to be cleaned. 

To Clean:
 

Disconnect the air tool from the air supply and pour or spray a generous 

amount of WD-40® into the air inlet with the trigger depressed. Connect the 
tool to the air supply, cover the exhaust port end with a towel and run in for-
ward and reverse directions for approximately 30 seconds. Follow the air motor lubrication instructions above 
after cleaning is completed to re-lubricate the tool.

After oiling or cleaning, cover the exhaust port with a towel and operate the tool for a  

few seconds to safely remove the excess oil. Clean the handle and surface of the tool of any oil residue. 
Failure to cover the exhaust port and clean the tool can result in serious injury.  

Note: Keep the towel away 

from moving parts!

 

    drastically reduce the tool life.
 

b. To tighten a fastener, turn the forward/reverse button to “F” (clockwise). Start the fastener by hand then  

 

  grip the ratchet wrench with your hand and place it on the fastener to be tightened. Gently squeeze the  

 

  trigger to tighten down the fastener. Drive the fastener until the ratchet stalls, release the trigger to stop  

 

  the tool, and then tighten further by operating the air ratchet wrench in the same manner as you would  

 

  operate a manually operated ratchet wrench.
 

NOTE: Do not use the air ratchet wrench to set torque. Always use a torque wrench to set    

 

 torque.

Disconnect the tool from the air supply before lubricating or changing sockets.

Summary of Contents for PXCM024-0270

Page 1: ...for choosing PORTER CABLE To register your new product go to www portercable com ServiceAndSupport ProductRegistration aspx Merci d avoir choisi PORTER CABLE Consulter le site Web www portercable com...

Page 2: ...loss of control of the tool PERSONAL SAFETY RISK OF INJURY Stay alert Watch what you are doing and use common sense when operating the tool Do not use the tool while tired or under the influence of dr...

Page 3: ...r another practical way to secure and support the work piece to a stable platform Holding the work by hand or against the body is unstable and is able to lead to loss of control RISK OF INJURY Do not...

Page 4: ...y from the sockets during tool use Securely fit the socket or attachment to the impact wrench Inspect anvil and retaining ring of tool prior to use Missing or damaged items should be replaced before u...

Page 5: ...air motor 3 Reconnect the tool to the air supply cover the exhaust port end with a towel and run in forward and reverse directions for approximately 30 seconds to remove excess oil NOTE If the tool r...

Page 6: ...in other countries Other trademarks may apply 888 895 4549 ONE YEAR LIMITED WARRANTY Porter Cable Industrial Tools the Company warrants that for a period of twelve 12 months from the date of purchase...

Page 7: ...on ce que vous faites et faites preuve de bon sens lorsque vous utilisez l outil N utilisez pas l outil lorsque vous tes fatigu en tat d bri t intoxiqu par une drogue ou lorsque vous avez pris des m d...

Page 8: ...pi ce dans une main ou contre votre corps vous tes dans une position instable qui pourrait tre la cause d un accident RISQUE DE BLESSURE Ne forcez pas un outil Utilisez plut t le bon outil pour l appl...

Page 9: ...Pour desserrer les fixations s assurer qu il y a suffisamment d espace derri re l outil pour viter de se coincer les mains L outil s loigne du joint filet lorsque l crou ou le boulon est desserr et re...

Page 10: ...ce d chappement ou de nettoyer l outil pourrait tre la cause de blessures graves Remarque Gardez la serviette l cart des pi ces mobiles GUIDE DE D PANNAGE CARACT RISTIQUES DE L OUTIL Couple maximum 50...

Page 11: ...alement tre applicables 888 895 4549 GARANTIE LIMIT E D UN AN Porter Cable Industrial Tools la Soci t garantit contre tout vice de fabrication et de main d uvre au premier acheteur au d tail seulement...

Page 12: ...utilice el sentido com n mientras utiliza la herramienta No utilice la herramienta si est cansado o bajo los efectos de f rma cos alcohol o medicamentos Un momento de distracci n mientras utiliza la h...

Page 13: ...Si sostiene la pieza con la mano o contra el cuerpo estar inestable y podr hacer que pierda el control RIESGO DE LESI N No fuerce la herramienta Utilice la herramienta adecuada para cada apli caci n L...

Page 14: ...s aseg rese primero que haya suficiente espacio libre detr s de la her ramienta para evitar que le atrape la mano La herramienta se alejar de la junta roscada a medida que la tuerca o tornillo es aflo...

Page 15: ...l orificio de escape y no limpia la herramienta puede ocasionar lesiones graves Nota Conserve la toalla alejada de partes m viles GU A DE SOLUCI N DE PROBLEMAS ESPECIFICACIONES DE LA HERRAMIENTA Par m...

Page 16: ...GARANT A LIMITADA DE UN A O Porter Cable Industrial Tools la Empresa garantiza que durante un per odo de doce 12 meses a partir de la fecha de adquisici n cambiar o reparar de forma gratuita y nicamen...

Reviews: