background image

5

Fig. 8

Fig. 9

Fig. 10

Fig. 7

Fig. 11

Fig. 12

Fig. 13

9.

Do not connect tool 

to pressure which

potentially exceeds 200 PSI (13.7 BAR).

10. Only use air hose that is rated 

for a

maximum working pressure of at least 150
PSI (10.3 BAR) or 150% of the maximum
system pressure, which ever is greater.

11. Connect tool to air supply hose

with a

coupling that automatically removes all
pressure from the tool when the coupling is
disconnected. Fig. 7.

12. Disconnect tool from air supply hose

before doing tool maintenance, clearing a
jammed fastener, leaving work area, moving
tool to another location, or handing the tool to
another person. Fig. 7.

13. Never use a tool

that is leaking air, has

missing or damaged parts, or requires repair.
Make sure all screws and caps are securely
tightened. Fig. 8.

14. Never use tool if safety, trigger or
springs 

are inoperable, missing or damaged.

Do not alter or remove safety, trigger, or
springs. Make daily inspections for free
movement of trigger and safety mechanism.
Fig. 8.

15. Do not use tool without safety
warning label.

If label is missing, damaged

or unreadable, contact your Porter-Cable
Service Center for a replacement. Fig. 9.

16. Only use parts, fasteners and
accessories 

approved by Porter-Cable.

17. Connect tool to air supply before

loading fasteners, to prevent a fastener from
being fired during connection. The tool
driving mechanism may cycle when tool is
connected to the air supply. Fig. 10.

18. Always assume the tool contains
fasteners.

No horseplay. Respect the tool as

a working implement. Fig. 11.

19. Operator and bystanders wear hard hat

to safeguard against possible injuries. Fig.
12.

20. Do not load fasteners

with trigger or

safety depressed, to prevent unintentional
firing of a fastener. Fig. 13

Summary of Contents for FN250A

Page 1: ..._________________________ Serial No _______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instruction...

Page 2: ...in conformity with the regulations EN292 2 section 3 of 1992 EN292 1 section 5 of 1992 EN1050 1993 EN792 13 2000 E ESPANOL DECLARACION DE CONFORMIDAD CE Declaramos bajo nuestra sola responsabilidad q...

Page 3: ...d the manual and pay attention to these sections SAFETY GUIDELINES DEFINITIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS Improper operation or maintenance of this product could result in s...

Page 4: ...manual for triggering options See Using the Tool with Selectable Triggering Options section of this manual 5 Never point tool at yourself or others in work area Fig 3 6 Never use oxygen or other bott...

Page 5: ...ightened Fig 8 14 Never use tool if safety trigger or springs are inoperable missing or damaged Do not alter or remove safety trigger or springs Make daily inspections for free movement of trigger and...

Page 6: ...red 25 Do not drive fasteners on top of other fasteners or with the tool at too steep an angle the fasteners can ricochet causing personal injury Fig 15 26 Do not drive fasteners close to the edge of...

Page 7: ...e filter will remove most of these contaminates and significantly prolong the life of the tool If an in line oiler is not available place five or six drops of Porter Cable Air Tool Oil into the tool s...

Page 8: ...ower A Fig 19 all the way to the rear until it latches 3 Insert a strip of approved fasteners see Fig 20 Orient fasteners with points down Slide fasteners forward to the front of the magazine The maga...

Page 9: ...rom the factory with a restrictive fire trigger that only allows the tool to be fired this way and is less likely to fire an unwanted fastener An alternate bottom fire trigger is available The bottom...

Page 10: ...y other repair The depth to which a fastener is driven is controlled by the depth adjustment knob A Fig 26 The depth of drive is factory adjusted to a nominal setting Test fire a fastener and check de...

Page 11: ...SERVICE AND REPAIRS All quality tools will eventually require servicing or replacement of parts due to wear from normal use These operations should ONLY be performed by either an AUTHORIZED PORTER CAB...

Page 12: ...of original purchase We will repair or replace at our option any part or parts of the product and accessories covered under this warranty which after examination proves to be defective in workmanship...

Page 13: ...731 541 6042 pour obtenir de l aide pour en rep rer un Pour obtenir des pi ces et accessoires pour les produits Porter Cable Delta s adresser tout distributeur Porter Cable Delta centre de service ag...

Reviews: