5
1.4 Dimensions and Cut-outs
MODEL
HIEGHT
(Adjustable Feet)
DEPTH
(Including Rear Vent)
WIDTH
60 cm
24 Inches
92 cm
36 Inches
64 cm
25 Inches
60 cm
24 Inches
90 cm
26 Inches
92 cm
36 Inches
64 cm
25 Inches
90 cm
35.5 Inches
1.5. CONNECTION TO THE GAS SUPPLY: CURRENT INSTALLATION STANDARDS
The cooker should be connected according to local
regulations, using either a rigid or flexible connections.
a) For building in: Use a continuous flexible stainless steel
pipe, as per current installation standards, which can be
extended to a maximum of 2000 mm.; the ends of the pipe
must be fitted with an ISO 228/1coupling and gasket or an
ISO 7/1 threaded coupling with mechanical gasket.
b) For free standing: A non-metallic flexible pipe can be used
as long as it complies with current standards and the
following installation instructions are observed: the pipe
must be longer than 400 mm and shorter than 1500 mm; it
must not exceed 50àC in any point; it is not pulled or
twisted; it cannot be choked and the entire edges, sharp
corners or other similar hazards.
Before connecting the non-metallic flexible pipe, the pipe holder and gasket supplied with the
cooker and/or available form the reseller must be fitted to the pipe/gas train on
the back of the cooker.
c) A certified gas plumber must complete the installation and meet with local regulation
requirements for gas connections. Where the unit has an armour cable a certified electricain
must complete the electrical connection. The white, or neutral wire will not be used and must
be capped using a marrette.
1.6. CONNECTION TO THE ELECTRICITY SUPPLY
The flexible mains lead is supplied connected to a fused plug fitted with a fuse of 13 amp
capacity. If you need to replace the plug for any reason, it should be carried out as outlined
below:
WARNING: THIS APPLIANCE MUST BE EARTHED
.