background image

 

 

Source: https://portgmbh-my.sharepoint.com/personal/mt_port_de/Documents/manuals/ecan9_manual.docx

 

 

Version: 1.0

 

Confidential

 

12/13

 

 

 

For each CAN interface the TCP server port and the bitrate can be set individually. Bitrate settings 
for all services running on the same CAN interface must be equal. So the settings for CANopen 
Server, CAN Server and CAN logging must be the same on a CAN interface. 
 

4.4

 

CAN logging 

 
The device offers the logging of CAN message to a SD Card. The configuration of the logging can 
be set up via the “CAN logging” page. 
 

 

 

For each CAN interface, bitrate and logfile size can set individually. Bitrate settings for all services 
running on the same CAN interface must be equal. So the settings for CANopen Server, CAN 

Summary of Contents for EtherCAN

Page 1: ...EtherCAN EtherCANopen Gateway Art_No 0540 30 EtherCAN Art_No 0540 31 EtherCANopen english version port GmbH Regensburger Str 7 D 06132 Halle Saale...

Page 2: ...port_de Documents manuals ecan9_manual docx Version 1 0 Confidential 2 13 History Version Created Validated Released Date Name Date Name Date Name 1 0 2015 08 03 Marcus Tangermann 2015 08 04 Sten M ck...

Page 3: ...nfiguration via Webinterface 5 4 1 Basic Settings 5 4 1 1 General concepts 5 4 1 2 Login to the web interface 6 4 1 3 Basic configuration 7 4 1 4 Date Time 8 4 1 5 SD Card 8 4 1 6 Configuration Manage...

Page 4: ...two CAN interfaces and connects decentralized CAN or CANopen networks with the classic Ethernet network The TCP IP protocol is used for Ethernet communications while the CAN bus supports both the tra...

Page 5: ...a a recent web browser When using factory defaults the device has the IP address 192 168 199 22 The following section provides an overview of the configuration of the EtherCAN ARM9 device via a web br...

Page 6: ...age will be shown By entering the login information for User and Password the user has the possibility to configure the gateway in accordance with its requirements When using factory defaults the foll...

Page 7: ...er basic settings of the device The basic configuration page allows the setting of IP address The IP address where the device is reachable This address applies to the web interface and to CAN open ser...

Page 8: ...f the device User Password Username and password of the web interface 4 1 4 Date Time The internal clock of the device can be set either manually or via central time servers using the NTP protocol Two...

Page 9: ...of the license data for the CANopen Server if not already delivered via the factory defaults A configuration can be stored or loaded via the Configuration Actions section There is also the possibility...

Page 10: ...on to the CANopen server contained in this device port provides a graphical user interface CANopen Device Monitor to communicate with CANopen devices using the CANopen server Please see CANopen Device...

Page 11: ...The CAN Server implements a CAN to TCP gateway which allows monitoring of CAN based communication via TCP connection In addition to the CAN Server contained in this device port provides a graphical us...

Page 12: ...CAN interface must be equal So the settings for CANopen Server CAN Server and CAN logging must be the same on a CAN interface 4 4 CAN logging The device offers the logging of CAN message to a SD Card...