Setting
Description
0
On
1
Off
2
On and Off
Parameter 7: BASIC command value sent to 2nd Association Group on
On
event
This is the BASIC command value sent in case of
On
event.
Size: 1 Byte, Default Value: 255
Setting
Description
0 - 99
Value
255
Value
Parameter 8: BASIC command value sent to 2nd Association Group on
Off
event
This is the BASIC command value sent in case of
Off
event.
Size: 1 Byte, Default Value: 0
Setting
Description
0 - 99
Value
255
Value
Parameter 9: Time Delay of
Off
command frame
Off command is sent after a delay defined in this parameter.
Size: 2 Byte, Default Value: 0
Setting
Description
0 - 32400
seconds
Parameter 10: Time Delay of
Off
command frame
Off command is sent after a delay defined in this parameter.
Size: 2 Byte, Default Value: 0
Setting
Description
0 - 32400
seconds
Parameter 11: Delay of Tamper Alarm Cancellation
Time a tamper alarm is delayed.
Size: 2 Byte, Default Value: 0
Setting
Description
0 - 32400
seconds
Parameter 12: Reporting Tamper Alarm Cancellation
This parameter defines if the alarm cancellation event is reported.
Size: 1 Byte, Default Value: 1
Setting
Description
0
Do not send Report
1
Send Report
Parameter 13: Central Scene Event Functionality
This parameter enables/disables the central scene function.
Size: 1 Byte, Default Value: 0
Setting
Description
0
Disabled
1
Enabled
Parameter 14: Tilt Sensor Functionality
This parameter enables/disables the tilt function.
Size: 1 Byte, Default Value: 1
Setting
Description
0
Disabled
1
Enabled
Technical Data