Parameter 5: Heavy Rain
This threshold defines when a heavy rain condition is hit. In most countries this is defined as > 15 mm rain per hour. The default value however is to turn this
function off.
Size: 1 Byte, Default Value: 255
Setting
Description
0 - 255
mm per hour
Parameter 6: Heavy Rain Start Command
This BASIC Set Command value is sent out into Association Group 3 when the device detects start of heavy rain
Size: 1 Byte, Default Value: 99
Setting
Description
0 - 99
Basic Set Value
Parameter 7: Heavy Rain Stop Command
This BASIC Set Command value is sent out into Association Group 3 when the device detects stop of heavy rain
Size: 1 Byte, Default Value: 0
Setting
Description
0 - 99
BASIC Set Value
Technical Data
Dimensions
132x132x139 mm
Weight
219 gr
Hardware Platform
ZM5202
EAN
4251295700168
IP Class
IP 55
Battery Type
2 * AAA
Device Type
Routing Multilevel Sensor
Generic Device Class
Multilevel Sensor
Specific Device Class
Routing Multilevel Sensor
Firmware Version
01.01
Z-Wave Version
04.05
Z-Wave Product Id
0x0154.0x0004.0x0011
Supported Command Classes
Basic
Sensor Multilevel
Meter
Association Grp Info
Device Reset Locally
Zwaveplus Info
Configuration
Manufacturer Specific
Powerlevel
Firmware Update Md
Battery
Wake Up
Association
Version
Controlled Command Classes