Setting
Description
0 - 99
Basic Set Command Value
255
Basic Set Command Value
Parameter 5: Central Scene ID for User Codes
This parameter defines if different user codes shall cause individual or similar scene ID sent to the main controller.
Size: 1 Byte, Default Value: 0
Setting
Description
0
Constant Scene ID 20 for all User Codes
1
Individual User Codes 1 ... 20
Parameter 6: Buzzer Confirmation
Size: 1 Byte, Default Value: 1
Setting
Description
0
Disabled
1
Enabled
Technical Data
Dimensions
120x75x25 mm mm
Weight
230 gr
Hardware Platform
ZM5101
IP Class
IP 44
Battery Type
4 * AAA
Device Type
Kepad
Generic Device Class
Portable Controller
Network Operation
Portable Controller
Firmware Version
01.00
Z-Wave Version
6.51.10
Z-Wave Product Id
0115.0100.0103
Supported Command Classes
Basic
Sensor Binary
Association Grp Info
Device Reset Locally
Central Scene
Zwaveplus Info
User Code
Configuration
Alarm
Manufacturer Specific
Powerlevel
Firmware Update Md
Battery
Wake Up
Association
Version