Explanation of Z-Wave specific terms

Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated
wall controllers.

Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.

Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.

Inclusion — is the process of adding new Z-Wave devices into a network.

Exclusion — is the process of removing Z-Wave devices from the network.

Association — is a control relationship between a controlling device and a controlled device.

Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.

Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.

(c) 2019 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwave.eu. The template is maintained by 

Z-Wave

Europe GmbH

. The product content is maintained by 

Z-Wave Europe GmbH 

, Supportteam, [email protected]. Last update of the product data: 2018-10-19

15:23:04

Summary of Contents for POPE004001

Page 1: ...EN 14604 and satisfies all legal requirements The smokebox is made of steel and antistatic plastic A button on the device can be used to test the smokebox the electronics and the battery In addition the device has an integrated test functionality to make manual tests with Aerosol unnecessary The battery warning gets send for at least 30 days During this time the smoke sensor stays fully functional...

Page 2: ... not placed right between the two mounting ring structures the detector can t be mounted to the ring Please follow the recommendations about amount as position of the sensor in your home as given above Avoid to place the sensor into the angle of walls prefer positions in the middle of the room Inclusion Exclusion On factory default the device does not belong to any Z Wave network The device needs ...

Page 3: ... if both devices use the same frequency 3 Remove all dead devices from associations Otherwise you will see severe delays 4 Never use sleeping battery devices without a central controller 5 Dont poll FLIRS devices 6 Make sure to have enough mains powered device to benefit from the meshing Firmware Update over the Air This device is capable of receiving a new firmware over the air The update functio...

Page 4: ...active 01 active default Parameter 6 Status of automated meshing of battery alarms This smoke detector can automatically inform other smoke detectors of same type about battery alarms They will then also turn on the siren This function is a requirement of wireless networked smoke detectors Size 1 Byte Default Value 01 Setting Description 00 inactive 01 active default Technical Data Dimensions 0 10...

Page 5: ...Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to announces that is able to communicate Node Information Frame is a special wir...

Reviews: