Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different
brands.
Installation
Please refer to the installation guide of the smoke sensor for information about how and where the smoke sensor should be installed. The installation guide
complies with the norm DIN EN 14676.
Remove the bracket from the detector main unit by rotating it counter-clockwise.
Place the bracket where you are going to install the detector. In each of keyhole slots, draw a mark to locate plastic anchor and screw. Using a 3/16-
inch (5mm) drill bit, drills two holes at the marks and insert plastic anchor, and attached the bracket by using the screws.
Open the battery compartment (1) to activate the battery, and then close the cover.
The optional external power supply will connect to the connector (5). The internal battery must stay inside the detector even when the external power
supply is connected.
Mount the smoke detector to the mounting ring. Make sure the hooks of the detector are placed between the hook and the twist stopper (2) of the
mounting base (arrows in image above). Then turn about 15 % clockwise. (Hint. If the detector hook is not placed right between the two mounting
ring structures the detector can‘t be mounted to the ring).
Please follow the recommendations about amount as position of the sensor in your home as given above. Avoid to place the sensor into the angle of walls,
prefer positions in the middle of the room.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate
with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave
network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right
on the device.
Inclusion
A single click on the button (3) includes the device. If the button is pressed for at least 2 seconds the inclusion will be done without the (Security Command
Class ).
Exclusion
A single click on the button will exclude the device.
Product Usage
In case smoke is detected by the smoke detector the device will sound, the red LED will blink and the wireless module will issue a Z-Wave alarm command
to the main controller and other associated devices. A low battery will be indicated on short siren noise plus the Z-Wave controller will be informed using
Battery Low warning commands.