Collector Silencer (119)
Collector End (121)
Collector End Cap (120)
Collector End Nut (122)
Mandrel Collection System (MCS) – ProSet
®
3400 MCS
For safety purposes, removing the Collector from the tool automatically turns the MCS suction OFF. Refitting
the Collector turns the MCS suction ON.
Cleaning the Collector Silencer
For optimum performance, the Collector Silencer should be cleaned at regular intervals as per the
“Preventative Maintenance Schedule”.
!
Note: UNPLUG AIR SUPPLY while servicing Collector to avoid INJURY.
1. CLEAN
THE
COLLECTOR
:
•
Remove and empty the Collector (113) by turning counterclockwise.
•
Remove the Collector End Nut (122) (17mm wrench) and remove the Collector End Cap (120).
•
Remove the Collector Silencer (119).
•
Clean and remove debris from all components.
Collector Body (118)
MCS suction ON
MCS suction OFF