Install a check valve and/or Hartford loop a minimum of 18 inches higher
than the top of the chlorinator BETWEEN the heat pump and any automatic
chlorinating devices. Follow the chlorinator manufacturer's instructions.
Improper installation of erosion-type automatic chemical feeders can result
in serious damage to the heat pump.
IV. Control Panel
Your heat pump incorporates controls and indicators to ensure its safe, reliable operation.
Water Temperature Control:
Pool water temperature is controlled by the heat pump thermostat
on the unit control panel, which contains a switch and 2 thermostats, one for setting a heat
temperature and the other for setting cooling temperature. The switch can operate an optional
external control system, or can switch between heat and cool.
NOTE: The heat pump will not run when the Remote position is selected
and there is no remote control system attached.
Page 6