4
2.
ELECTRONICS UNIT
2.1.
First commissioning
The first time you power up the electronics unit, carry out the programming below.
Successive
menus
Possible settings
Navigation
Languages
ENGLISH
•
French
•
English
•
Deutsch
•
Español
•
Italiano
•
Nederlander
•
Portugués
For each menu, select a setting with the
buttons, then confirm with the
OK
button.
pH setpoint
From 6.8 to 7.6, in increments of 0.1
pH Prop. Range
From 0.05 to 0.15, in increments of 0.05
Upper Limit
From (
pH setpoint
+ 0.2) to 8, in increments of 0.1
Lower Limit
From 6 to (
pH setpoint
- 0.2), in increments of 0.1
Date
01/01/01
Day/Month/Year
Time
XX:XX
Hour/Minute
Software Version
XX.XX
None (read-only display for a few seconds)
2.2.
LEDs
Colour
Status
Possible meanings
Green
Continuously on
Electronics unit on
Flashing
•
pH corrector injection in progress
Red
Continuously on
•
Electronics unit powered off
•
Alert activated
Flashing
Alarm activated
2.3.
Screen
2.3.1.
Overview
Display
Possible meanings
Steady
•
Read-only information
•
Confirmed information
•
Alert activated
Flashing
•
Automatic operation in progress
•
Information awaiting confirmation
•
Alarm activated