9
2.6.6.
Programming the ‘Info Gel CL’ alert
→
The ‘Info Gel CL’ alert is a reminder to fill/change the electrolytic gel on the same day this alert is activated.
Menu
Sub-menu
Activation delay after the last refill/change of electrolyte gel
Possible settings
Default setting
Dosing
Cl gel
Cl gel
Alarm XXXd
From 30 to 180 days, in 30-day increments
90 days
2.6.7.
Setting the proportional range of the chlorine regulation
→
The proportional range of the chlorine regulation is used to determine the measuring range in which the chlorine
injection pump is controlled proportionally to the deviation between the setpoint and the measurement.
→
The smaller the range, the greater the injection for the same chlorine measurement. For small pools, a range of 0.3
ppm is preferable to avoid significantly exceeding the setpoint.
Menu
Possible settings
Default setting
Dosing
Prop. range CL
From 0.1 to 0,3 ppm, in increments of 0.1 ppm
1.0 ppm
2.6.8.
Setting the chlorine regulation cycle time
→
The cycle time is used to set the injection cycle of the pump, and, therefore, to take into account the reaction time of
the pool between injection and measurement.
→
The shorter the cycle, the more responsive the regulation will be. For very small pools, such as spas/Jacuzzis, use a
30 second cycle.
Menu
Possible settings
Default setting
Dosing
CL cycle
From 30 to 300 sec, in 30-second increments
60 sec
2.6.9.
Setting the chlorine regulation thresholds
Menu
Sub-menu
Functions
Default setting
Dosing
CL limits
CL limits
Upper Limit
Upper chlorine value (ppm) above which the corresponding
alarm will be activated
5 ppm
CL limits
Lower Limit
Lower chlorine value (ppm) below which the corresponding
alarm will be activated
0.5 ppm
2.6.10.
Setting the start-up delay for chlorine regulation
→
The start-up delay is used to set the stabilisation time of the amperometric probe. This delay will be activated when
the water flow in the measuring chamber is restored. During this time, chlorine regulation is automatically disabled.
→
In the event that the electronics unit is switched on or a ‘
CL sensor error
’ alarm is triggered, a polarisation time of
30 minutes will be applied regardless of the delay value pre-set in this menu.
Menu
Possible settings
Default setting
Dosing
Start-up delay
From 5 to 30, in 5 min increments
30 min