Remedy of faults
Malfunction
Cause
Remedy
The unit does not deliver any air or the amount
delivered is insufficient.
The aeration stone has not been in the water
for long enough.
Wait. The pores of the dry aeration stone will
completely open after approx. two hours in the
water.
The aeration stone is soiled.
Clean
Air hose kinked or porous
Lay the air hose without kinks or replace.
Air hose not correctly fitted
Check the air hose.
Insufficient sunlight
—
No suitable operating mode selected
Check the operating mode (
→
Installation and
connection)
Cleaning
N O T E
The unit will be damaged if moisture penetrates the motor compartment.
•
Do not clean the unit under running water.
•
Do not submerge the unit!
•
Protect the air intake socket from the ingress of water.
•
Do not use aggressive cleaning agents or chemical solutions as they could attack the housing or impair the function
of the unit.
•
Recommended cleaning agent for removing stubborn limescale deposits:
– Vinegar- and chlorine-free household cleaning agent.
•
Clean the solar module with a damp cloth and wipe dry.
Wear parts
The following components are wear parts and are excluded from the warranty:
•
Aeration stone and air hoses
Storage/overwintering
•
Store the unit in a dry and frost-free place.
•
Set the switch on the unit to the position "O".