S e r v i c e t r a i n i n g
000
29022000
4.3
A
B
Adjustment and service
instructions
Diameter measuring
Before calibrating of the diameter, you should check the
following:
1.
The tree travels in the centre of the harvester head. If
necessary, adjust the tree (a round one) to the centre
using the reaction brace .
2.
Check that the measurements
A
and
B
are equal. If
the difference is greater than 5 mm, an adjustment has
to be made. A half revolution of the reaction brace is
equivalent to a 5 mm change in the difference between
measurements A and B. Recheck the measurements.
3.
When the feeding rollers are closed, the sensor
reading must be 30. If the reading is something else, it
can be adjusted by turning the sensorbody.