background image

4-IN-1 GAS DETECTOR 

   

 

 

1

ID passed 

 

2

ID lock   

3

Success indicator   

4

Failure indicator 

 

5

Alarm 

 

6

Vibration 

 

7

Alarm 

 

8

Battery indicator 

 

9

Measurement result 

 

10

Type of gas detected and its unit 

 

11

Menu setup 

 

12

Calibration 

 

13

Save data 

 

14

Zero - calibration 

 

15

Type of gas 

 

16

Measuring unit: LEL, Vol 

17

Warning (Level 2): 

 

18

Reserved mark 1:   

WWW.PONPE.COM

Summary of Contents for BX615

Page 1: ...BX615 BX615 BX615 BX615 BX615 EX O2 H S 2 CO 4 IN 1 GAS DETECTOR ...

Page 2: ...TABLE OF CONTENTS I DESCRIPTION 2 II SPECIFICATION 3 III OPERATION INSTRUCTIONS 4 IV CALIBRATION 10 V MAINTENANCE 20 VI STORE CONDITION 21 VII ACCESSORIES 21 ...

Page 3: ...4 IN 1 GAS DETECTOR 1 I DESCRIPTION WARNING INDICATOR GAS SENSORS COVER SCREW BUZZER LCD SCREEN POWER UP DOWN OK WWW PONPE COM ...

Page 4: ...y life 18 hours of continuous use 15 hours for flammable gas detection Sensor type electro chemical flammable gases i e H2S CO and O2 as catalysts TYPE OF GAS RANGE ACCURACY MIN SCALE RESPONSE TIME O2 0 25 VOL 5 F S 0 1 30MINS Ex 0 100 LEL 5 F S 0 1 40MINS CO 0 1000ppm 5 F S 1ppm 40MINS H2S 0 100ppm 5 F S 1ppm 60MINS WWW PONPE COM ...

Page 5: ...0RH Dimension 126mm L 66mm W 32mm H Net weight 220 grams including charger III OPERATION INSTRUCTIONS 1 Power on Press the detector turn on after the buzzer goes off once 2 Power off Press and hold the LCD will count down for 5 seconds before the buzzer rings shortly after which the device will turn off If holding too shortly the detector will return back to measuring status 3 Low battery WWW PONP...

Page 6: ... no battery the Low Battery indicator will show on the LCD along with a text warning reading as Battery Low The device will shut off shortly after When the Low Battery indicator appears the device is suggested to be turned off and recharged for 4 to 6 hours The first three times of use require a full charge each time of more than 12 hours 4 Descriptions of function keys Power on off Up Down Power ...

Page 7: ...4 IN 1 GAS DETECTOR 5 Self testing Turn on backlight Turn on backlight Zero calibration Sensitivity level Confirmation WWW PONPE COM ...

Page 8: ...ted when a gas density is greater than the alarm threshold or press any button If performing routine check in a low light environment backlight can be activated manually by pressing the Up or Down keys once 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 19 20 9 10 WWW PONPE COM ...

Page 9: ...re indicator 5 Alarm 6 Vibration 7 Alarm 8 Battery indicator 9 Measurement result 10 Type of gas detected and its unit 11 Menu setup 12 Calibration 13 Save data 14 Zero calibration 15 Type of gas 16 Measuring unit LEL Vol 17 Warning Level 2 18 Reserved mark 1 WWW PONPE COM ...

Page 10: ...ill enter into meter by dissemination The normal flow of air can sufficiently carry the target gas into the detector at which point the device will provide a reading for the density of the targeted gas The dissemination method uses the aforementioned method to test and record density levels of various gases in the air The main advantage of this method is the short response and measurement time Whe...

Page 11: ...g mode The detector has two instant warning levels which are warning level 2 for toxic gas with higher density levels and warning level 1 for toxic gas with lower density levels The detector has another two accumulative effects mode STEL and TWA STEL is accumulative in 15minuts TWA is accumulative in 8 hours User can reset both warning level 1 and level 2 in setting mode Note STEL Shot Time Exposu...

Page 12: ... indicators The buzzer can be set to go off every 5 minutes as an indication that the detector is working properly 3 7 Model setting Note when detector is in the setting mode detector cannot take measurements User setting Turn on or off the warning mode Behaviours of the flash and sound indicators Vibration and Set points for warning level 1 and warning level 2 IV Adjustment 4 1 Power on WWW PONPE...

Page 13: ...arning light buzz vibration go off subsequently once one second later the current version of the software will be on display one second after warning level 1 will be displayed for 2 seconds 2 seconds later warning level 2 will be display for another 2 seconds 2 seconds after the STEL will show for 2 seconds ...

Page 14: ...ayed for 2 seconds 2 seconds later the detector initiates by counting down 10 seconds After the initiation process and self checking the device will enter measurement mode Error messages will be displayed if according to each error type accordingly WWW PONPE COM ...

Page 15: ...down buzzer goes off 5 times in shorter audio after which the buzzer rings one more time in longer audio the the device is powered off 4 3 Warning setup in measuring status press key in 5seconds buzzing 1 time in shorter audio get into ID setting select key or then press key OK for confirm display in 2 seconds WWW PONPE COM ...

Page 16: ...adjust target value Press key OK for confirm So then get into CO s warning level 2 status If do not modify press key get into next step CO s warning level 2 setting status Due time press or to adjust target value press OK for confirm so then get into next next step H2S s warning level 1 setting status If do not modify press get into next step WWW PONPE COM ...

Page 17: ...p H2S s warning level 2 status If do not modify press get into next step H2S s warning level 2 setting status Due time press or to adjust target value press OK for confirm so then get into next step O2 s warning level 1 status If do not modify press get into next step O2 s warning level 1 setting status Due time press or to WWW PONPE COM ...

Page 18: ...o not modify press get into next step O2 s warning level 2 setting status Due time press or to adjust target value press OK for confirm get into next step EX s warning level 1 setting status If do not modify press get into next step EX s warning level 1 setting status Due time press or to adjust target value press OK WWW PONPE COM ...

Page 19: ...into measuring status EX s warning level 2 setting status Due time press or to adjust target value press OK for confirm get into measuring status If do not modify press get into measuring status 4 4 Zero calibration in measuring status press in 5 second buzzing 1 time in shorter audio get into ID setting WWW PONPE COM ...

Page 20: ...ill return to measuring status after 2 second get into zero calibration status CO H2S EX value will be 0ppm or 0 LEL O2 value will be 20 9 VOL it is basic standard level and display 0 or 20 9 VOL in this status press OK return to testing status if it is not in right status disply Err press for return WWW PONPE COM ...

Page 21: ...r confirm get into unlock disply in 2 second If wrong ID it will return to measuring status after 2 second get into CO calibration disply and flash 300ppm in CO area And then show real value in CO area Press for skip get into H2S calibration if it is same as standard gas in 300ppm press OK for confirm if it is not same as standard gas WWW PONPE COM ...

Page 22: ...tuation press OK finish CO calibration and get into next step H2S calibration in H2S calibration disply 50ppm and flash in H2S area And then show real value in H2S area if it is same as standard gas in 50ppm press OK for confirm press for skip get into O2 calibration if it is not same as standardgas in 50ppm press or to adjustment press WWW PONPE COM ...

Page 23: ... into next step O2 calibration in O2 calibration it is pure nitrogen gas in 99 99 for O2 calibration so it display value in LCD Due time open gas valve allow gas flow into detector waiting for stable situation press OK finish O2 calibration and get into next step EX calibration press for skip get into EX calibration in EX calibration disply and WWW PONPE COM ...

Page 24: ...ss OK for confirm press for skip get into measuring status if it is not same as standard gas in 50 LEL press or to adjustment press OK for confirm Due time open gas valve allow gas flow into detector waiting for stable situation press OK finish EX calibration and get into measuring status 4 6 Flow chart checking WWW PONPE COM ...

Page 25: ...buzzer goes off 1 time in shorter audio get into flow chart checking status The detector will display maximum value in measurment press OK the detector will display minimum value in measurment press OK it will display STEL value average in 15 minuts WWW PONPE COM ...

Page 26: ...4 IN 1 GAS DETECTOR 24 press OK it will display TWA value average in 8 hours press OK get into measuring status WWW PONPE COM ...

Page 27: ...echarge please operate in safety place 5 5 to avoid any dropdown or almighty crash and shake 5 6 When detector working in irregular display or incontinuous buzzing it will be cased by low battery it will be running again after recharge 5 7 the detector should be not stored or used neither underthe circumstance with caustic gas such as Cl2 not under the other rugged circumstances including excessiv...

Page 28: ... condition 6 1 warranty period is 12 month 6 2 The manufacturers disclaim all responsibility for damage caused by misuse Accessories 7 1 Detecor 1pc 7 2 User Manual 1pc 7 3 Calibration cap 1pc 7 4 Charger 1pc VI VII WWW PONPE COM ...