1
.
Power Indicator doesn’t work.
1
)
Check if there is electricity in power supply.
2
)
Check if the input fuse is blown. If the fuse is broken, check if the input power is correct and
change the fuse. There are two fuses in the box which is under the mains jack. One is for
working, the other is for reserve.
3
)
If the fan works well and the kit works normally online, it might be the indicator’s circuit
problem which has no effect on output values.
2
.
Voltage short circuit or overheat alarm
1
)
Pull out all external connections. If the alarm disapears, it indicates there is no problem with
the kit.
2
)
If the alarm doesn’t disapear, measure the voltage. If the voltage is low, please improve
power supply.
3
)
If the alarm doesn’t disappear, measure voltage output terminal by multimeter. If there is
bigger DC voltage or lower AC voltage, it indicates the kit is horken. Please contact the
after-sales.
3
.
Cannot connect to computer
The computer connecting with the suitcase must install an Ethernet card 100MBytes / s. If it can’t link,
please check following points:
1) Check the Ethernet connection.
2) Check the power supply is on.
3) Check if the model selected is “
In Remote control…
”.
4) Check the IP address of computer and kit are correct. The default IP for kit is 192.168.1.133.
The computer IP address should be in the same internet setting as 192.168.1.XXX. XXX
should not be 133. If the IP is not correct and can’t be changed, please pull out the internet
cable and change it again.
5) Check if the communication setting in “System set” is “Ethernet”.
6) Turn off antivirus software, and then test again.
7) Sometiems computer system may affect online result, please change computers.
10
.
Troubleshooting