PA30Bi-H Power Amplifier User Manual
26
object respectively, and then inactivate the pause function and input the simulation signal,
the amplifier will enter into simulation status.
7.3.2 High power output
In case of high current output and large load impedance (e.g. several protection devices
are connected to each other in serial), you can activate the high power function for a short
time. Inactivate the high power function as soon as this high current test was done.
Note:
1. Normally high power button is not activated (high power switch light is off also).
2. For safety, never plug signal cable or load connection when there is current output.
7.3.3 Voltage/Current Output Display
If you want to monitor voltage or current output in real time, just switch the voltage or
current display buttons on the panel to corresponding position.
7.4 Amplifier Off
After all testing is finished, please terminate the simulator signal input, press Pause
button and turn off the power of the amplifier.