5-2 

Select  POSITON  SETUP  same  as  AREA  FENCE  and  press

then 

above right frame will appear. Each position of square point will be selected by 

arrow and press

button to set.

 

                                                                                                                                                                                                                                                         

 

5-3 

Turn “ACTIVATION” to ON and press 

button and set, Release is OFF.

 

   

   

                                                                                                                                                                                                                                                         

5-4 

When do not want to indicate MASK SETTING AREA on frame, set DISP MODE           

to be turned to OFF, When want to be indicated, set to ON.         

 

  6.MAIN SETUP/CAMERASETUP/CAM ID setting=Camera No. setting 

           

 

 

Summary of Contents for PONI-P100-IVA

Page 1: ...1 IP Intelligent Video Analysis Camera PONI S100 IVA PONI P100 IVA IP Camera VA Setup Manual English PONICO KOREA CORPORATION PONICO CANADA ENTERPRISE CORPORATION ...

Page 2: ...nstallation This manual is subject to camera position being fixed a Installation height in between 2 5m and 10m b Distance between camera and object sensing distance In between 5m and 30m c Size of objective in camera view if vertical frame is presumed as 100 user will set up height of objects in between 10 and 80 2 Condition Following case might be detected erroneously as moving object a Reflecti...

Page 3: ...A IP Camera Set Up 1 Web Browser Connection 1 1 IP Connection By inputting IP address of a camera such as 192 168 1 100 in Web browser above screen will be displayed Log in by inputting of ID and Password ...

Page 4: ...r OSD by checking off 2 2 FIT Adjust Image Output to the Viewer size 2 3 Video 1 Video 2 Selection of video output By setting Video Stream can be separate Video 1 for Viewing and Video2 for Recording 2 4 Screen Capture is saved as JPEG File 2 5 Full Screen View in Full screen ...

Page 5: ...imary for VIDEO1 setup Secondary for VIDEO2 setup Codec H 264 MPEG4 Resolution VGA QVGA Video Quality Bit rate bps FPS Select Frame rate 3 2 Audio Set Up Enable Using AUDIO by ON OFF Mode Full Duplex both directional use Input Gain Output Gain Set up of input output volume ...

Page 6: ...Mail Pre alarm To set number of frame to be recorded BEFORE occurrence of Event Post alarm To set number of frame to be recorded AFTER occurrence of Event Notification Intev To set time interval of notification of Event MOTION DETECTION REGION SETTING will be referred to B VA of page 10 ...

Page 7: ...iewer User ID PW will be assigned up to 5 people 5 New Work Set Up 5 1 IP Address Filtering To setup filtering of IP address for PC being accepted or denied for an authorized connection 5 2 Server Setting To set up camera server name Control port Data port For connection from outside Control port number is required ...

Page 8: ...YSTEM Setting 6 1 DATE and TIME Setting Current Server Time Time of present camera Manual Setting To input time by manual Sync with PC To set time with PC time by synchronizing Sync with NTP To set time with NTP Server by synchronizing 6 2 Maintenance Firmware F W upgrading ...

Page 9: ... camera Access Log Show status quo of connection of user Event Log Show status of Event occurring IP camera setting except for Event setting under Web viewer of PONI S100 IVA had been explained from the above The next VA Video Analysis setting of IP camera Event setting of MOTION DETECTION REGION SETTING will be detail explained hereunder ...

Page 10: ... Main Menu 1 1 Press button open MAIN SETUP frame Select VASETUP by triangular arrow press BUTTON 1 2 Select VA ENABLE and activate to ON by triangular arrow And set by button 1 3 Press button After the MAIN SETUP fame disappears confirm words of VA starting on upper right corner of frame Sign of VA function activating ...

Page 11: ...be taken by camera when setting the sensitivity 1 6 VA SETUP OBJECT SIZE setting is to set the size of detecting object Small Middle Large Consider size and distance of objects to be taken by camera when setting the object size 2 MAIN SETUP FENCE SETUP LINE FENCE Setting a S100 Invader Detection Function LINE b P100 Counting Function LINE 2 1 Select FENCE SETUP by triangular arrow from MAIN SETUP ...

Page 12: ... Setting aline position will be shifted right and left or up and down by triangular arrow and selected by pressing button After Left point setting Right point will be set Same after setting lower point upper point will be set Points can be set individually 2 4 Small square dot in the center of line will show direction of moving forwarding object 2 5 Turn the ACTIVATION to ON and press button for s...

Page 13: ... Press button then setting frame will disappear As shown above Setting frame of LINE setting can be confirmed 3 MAIN SETUP FENCE SETUP AREA FENCE Setting a S100 Invader Detection Function Square AREA b P100 Counting Function Square AREA 3 1 FENCE SETUP Select AREA FENCE Press button then right above frame will appear Set Area from 1 through 4by selecting sequentially by and press button ...

Page 14: ... arrows and press button to set 3 3 Decide direction of sensing and alarming by DIRECTION IN to be alarmed when objects coming to inside from outside OUT to be alarmed when object going outside from inside S100 sends alarm P100 displays number of object counted 3 4 Turn ACTIVATION to ON and press button to set Release is OFF ...

Page 15: ...nfirmed 4 MAIN SETUP FENCE SETUP APPEAR DISAPPEAR Setting Function of sensing new object and disappearing object This function is not on the P100 4 1 FENCE SETUP Select APPEAR DISAPPEAR Press and above right frame appears From APPEAR FENCE 1 through 4 setting will be decided by selecting sequentially and press ...

Page 16: ...IMING ALARM TIMING is a time to alarming after occurrence of event incident such as disappearance or appearance of object 4 4 Turn ACTIVATION to ON and press button to set Release is OFF 5 MAIN SETUP VA MASK SETUP MASK Setting Function to delete sensing of redundant scenery and movement 5 1 Select VA MASK from MAIN SETUP and select MASK 1 through 4 sequentially to set and press button ...

Page 17: ...are point will be selected by arrow and press button to set 5 3 Turn ACTIVATION to ON and press button and set Release is OFF 5 4 When do not want to indicate MASK SETTING AREA on frame set DISP MODE to be turned to OFF When want to be indicated set to ON 6 MAIN SETUP CAMERASETUP CAM ID setting Camera No setting ...

Page 18: ... select CAM ID and can change CAM No 7 MAIN SETUP CAMERA SETUP COLOR SETUP Setting Camera Color Setting 7 1 From MAIN SETUP select CAMERA SETUP and press From CAMERA SETUP select COLOR SETUP and press Then following settings can be done Brightness Contrast and Saturation ...

Page 19: ... press From CAMERA SETUP select SCREEN FLIP FLIP To flip upper lower of screen Mirror To flip left right of screen MIR FLI To flip upper lower left right 9 MAIN SETUP CAMERA SETUP SHUTTER SPEED Setting Select Shutter Speed of Camera Sensor 9 1 From MAIN SETUP select CAMERA SETUP and press From CAMERA SETUP select Shutter Speed then select 50Hz or 60Hz ...

Page 20: ...nd press From CAMERA SETUP select OSD COLOR and decide color of VA character Color can be selected from WHITE BLACK RED BLUE and YELLOW 11 MAIN SETUP SYSTEMSETUP SYSTEM REST Seting REST VA Setting 11 1 From MAIN SETUP select SYSTEM SETUP and press From SYSTEM SETUP select SYSTEM REST and Reset by YES or NO ...

Page 21: ...d Reset by YES or NO In case of YES VA function is initialized it is necessary to Setup VA function from the beginning MAIN SETUP SYSTEMSETUP COUNT DISPLAY Setting Combined Function of S100 P100 Display both Alarm and Number Counted at the same time forLINE AREA From MAIN SETUP select SYSTEM SETUP and press FromSYSTEM SETUP set COUNT DISPLAY of LINE AREA by ON OFF ...

Page 22: ...LOW 14 MAIN SETUP VA SETUP OBJECT SIZE Setting Setting size of object that best fits for monitoring 14 1 From MAIN SETUP select VA SETUP and press From OBJECT SIZE input size of object to be monitored SMALL To monitor the object of its height is more than 1 8th of screen MIDDLE To monitor the object of its height is more than 1 6th of screen LARGE To monitor the object of its height is more than 1...

Page 23: ...ect VA SETUP and press From CAM SABOTAGE select ON If function to be not operated select OFF 16 Other Settings 16 1 From MAIN SETUP select FENCE SETUP and press From FENCE SETUP set ALAM OUTPUT When ALARM signal to be sent out ON not to be sent out OFF 16 2 From MAIN SETUP select SYS INFO and press This is to confirm F W version of the product The END ...