PoNET KBD48CNC User Manual Download Page 10

PoNET kbd48CNC manual 

 

10 

www.poscope.com 

 

Configuring the keyboard with Mach4 

 
The  easiest  was  to  configure  kbd48CNC  with  Mach4  plugin  is  to  enable  ‘kbd48CNC’  as  one  of  the 
peripherals in the ‘New device wizard’ when adding the PoKeys device to the plugin configuration. If 
this configuration is being done afterwards, follow these steps: 

1.

 

Open  PoKeys  plugin  settings  and  double-click  on  the  PoKeys  device  with  the  kbd48CNC 
device attached. 

2.

 

Switch to ‘Pendant’ tab and enable ‘Enable pendant mode’, ‘Map pandant signals to Mach4’ 
and ‘kbd48CNC’ options. 

This will configure the plugin with the default functionality of the kbd48CNC device. Note that some 
functions may not be available in Mach4. 
 

Default functionality in Mach4 

This is the default functionality supported: 

-

 

Cycle start: start the cycle 

-

 

Feed hold: pause 

-

 

Stop: stop immediately 

-

 

Reset: enable/disable function 

-

 

Optional stop: enable/disable optional stop feature 

-

 

Close: close current file 

-

 

Rewind: rewind the current job to beginning 

-

 

Block delete: block delete function in Mach4 

-

 

Goto 0’s: move to position 0 started if pressed for 1 second 

-

 

Spindle CW, Stop, CCW: start/stop spindle 

-

 

Spindle speed adjustment: increase/decrease or reset (100%) the spindle speed 

-

 

Feedrate adjustment: increase/decrease or reset (100%) the federate 

-

 

Jog On: enable/disable jogging 

-

 

Jog speed adjustment (Jog+/Jog-): increase/decrease jog speed 

-

 

Jog mode selection: switch between Continuous, Incremental or MPG jogging modes 

-

 

Jog axis selection: select between axes X, Y, Z, A, B or C 

-

 

Jog  step  selection:  switch between  preset  step  sizes  in  incremental  or  MPG  jogging  modes 
(configurable in Mach4 config) 

-

 

Jog action (+ / - keys) 

-

 

Rapid jog (b / - keys): enable/disable rapid jog function 

 
Other  functions  can  be  customized  -  to  customize  the  behavior  of  the  kbd48CNC  device,  IO  signal 
mapping or LUA scripting can be used  – keyboard key statuses and LED indicators are available via 
‘PoKeys_[serial number]_kbd48CNC’ device. 

 

 

Summary of Contents for KBD48CNC

Page 1: ...PoNET kbd48CNC User s manual Version 18 10 2019 ...

Page 2: ...is used with shall be fitted with a separate means of fail safe protection emergency stop capability and or system power removal This equipment may be connected to dangerous power sources including electrical power sources Dangerous voltage levels may be present at this equipment or at connected devices Measures must be taken to prevent persons from contacting voltage sources which may be present ...

Page 3: ... use of its functionality Two LEDs on the keyboard are used to indicate power supply and device status Power LED red color switches on immediately after power supply is connected while Status LED green color signals the current status of the device Solid On device is connected and working normally Slow blinking no connection to Pokeys device Fast blinking bootloader operation Solid Off device disa...

Page 4: ...PoNET kbd48CNC manual 4 www poscope com Front panel cutout dimensions ...

Page 5: ...ured device On the left all PoNET devices are listed Unconfigured PoNET devices will be listed as illustrated above To configure the new device double click on Unconfigured device icon and press any key on the device that you want to add you have a 10 seconds time window to do that If configuration process for a device was successful the green status LED will stop to blink and will be constantly l...

Page 6: ... keyboard manually without the use of the kbd48CNC aware application check the option Enable mapping to matrix keyboard option in the PoNET device settings Then close this dialog and click Send to device button and restart the application Open the Peripherals Matrix Keyboard menu where you can track your keyboard actions and define key mapping options ...

Page 7: ...PoNET kbd48CNC manual 7 www poscope com The following naming scheme is used for buttons on the kbd48CNC Matrix keyboard key indexing ...

Page 8: ...NC to the PoKeys device and configuring it in Mach3 Mach4 1 Connect the kbd48CNC to the PoKeys device with the provided cable 2 Connect the PoKeys device to PC 3 Open PoKeys configuration software and connect to your device 4 Go to Peripherals PoNET settings ...

Page 9: ...peat step 5 7 When using kbd48CNC with Mach3 Mach4 Enable mapping to matrix keyboard should not be checked In the bottom part of the dialog various test modes are available to test the keyboard these will function only when the PoNET settings dialog is open a LED test mode any key press will start a wave like pattern radiating from the key that was pressed b LED test mode 2 random LEDs will be ran...

Page 10: ...nction Optional stop enable disable optional stop feature Close close current file Rewind rewind the current job to beginning Block delete block delete function in Mach4 Goto 0 s move to position 0 started if pressed for 1 second Spindle CW Stop CCW start stop spindle Spindle speed adjustment increase decrease or reset 100 the spindle speed Feedrate adjustment increase decrease or reset 100 the fe...

Page 11: ...ard with Mach3 1 Open Mach3 it Mach3 PoKeys plugin is not yet installed follow the steps in PoKeys Mach3 plugin manual to install it 2 Go to Config Config plugins and click yellow CONFIG button for the PoKeys plugin 3 Select your PoKeys device and click Configure ...

Page 12: ...plugin setup from poscope com please download the file and use WinZip or similar program to extract the contents of the file 5 The previous step will load the default configuration for the keyboard To change the default setup go to PoKeys mapping tab and find kbd48CNC This section is used to setup the buttons in all three sections of the keyboard Function of a button is simply changed by selecting...

Page 13: ...PoNET kbd48CNC manual 13 www poscope com 6 To setup the keyboard LEDs under the keys go to kbd48CNC LED section 7 To save the settings click OK ...

Page 14: ... life support devices or systems and any other applications or purposes that pose a direct threat to human life 8 You should use the PoLabs products described in this document within the range specified by PoLabs especially with respect to the maximum rating operating supply voltage range and other product characteristics PoLabs shall have no liability for malfunctions or damages arising out of th...

Reviews: