Remedy of faults
Malfunction
Cause
Remedy
The unit does not perform its suction function
Drain hose incorrectly fitted
The non-return valve must be located at the
free end of the drain hose
Excessive height difference between water le-
vel and unit
Places the unit at water level height
The unit does not reach its full capacity
Dirt has accumulated in the foam filter, in the
suction tube or in the suction hose
Remove soiling
Dirt has accumulated in the area of the non-re-
turn valve at the drain hose preventing it from
closing properly
Remove soiling
The collection container does not run empty,
the unit does not prime
The collection container cannot drain
Lay the drain hose without kinks.
Provide slight gravity for the drain hose.
After draining, almost no water should remain
in the collection container.
Collection container and drain hose are soiled
Remove soiling
Low suction capacity
The more tubes are used, the higher the tube
frictional resistance. The suction capacity
reduces.
Hold the suction hose as flat as possible to im-
prove the suction performance
Wear parts
Filters and valve rubber elements are wear parts and are not covered by our warranty.
Maintenance and cleaning
How to proceed:
D
1. Switch off the unit and disconnect the power plug.
2. Disconnect the hoses.
3. Undo the side locking clips and remove the motor housing.
4. Undo the filter holder.
5. Remove the filter and rinse under running water.
– If the filter is damaged, replace it with an original filter.
6. Clean the container.
7. Clean the bottom of the motor housing.
8. Check the rubber valve in the drain hose and clean.
9. Reassemble the unit in the reverse order.
Storage/Over-winter
Storage
Empty out the collection container and clean the unit. Store in a dry, frost protected room, inaccessible to children.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Summary of Contents for MVAC