VISIT WWW.THEPONDBOSS.NET FOR PRODUCT INFORMATION AND TIPS.
6
EN
Presure Filter
• The Pond Filter may require cleaning from time to time for optimal performance.
• Before cleaning, always disconnect the pump from the power source that is
connected to the filter.
• Remove the filter pads and clean with water and when they are visibly soiled.
• Return the filter pads with the fine filter pad (blue) in first, and the coarse filter pad
(black) on top.
NOTE: The bioballs contain beneficial bacteria. At least once a year the entire system
should be disassembled and cleaned thoroughly using warm water. This should not
be done during the warm season as it may take up to 8 weeks to re-establish the
environmental balance. The best time of the year to “breakdown” your system is in
early spring before the water temperatures begin to rise. This is also the ideal time to
replace the filter pads.
• Filter pads should be replaced annually or when visibly deteriorating. Use pondboss
Replacement Filter Pads item #52363 (#FRP) for a new fine and coarse filter pad.
• Reconnecting the pump to the power source when you are finished.
For replacement parts, contact Customer Care,
Monday - Friday
:
1-888-755-6750 [email protected]
REPLACEMENT PARTS
B
O-ring
C
Cover
D
Lid
H
Adapter
I
Gasket
J
Locking ring
K
Small adapter
L
Small gasket
M
Tank
N
Lamp housing
O
Lamp holder gasket
P
Bulb holder
Q
Glass tube assembly
R
O-ring 2
TROUBLESHOOTING
IF THE UV LIGHT FAILS TO OPERATE:
• Check to make sure the power cord is plugged in and the light is getting power.
• Check to make sure that the lamp holder is screwed completely into the body. (This
product will not operate unless it is fully assembled with the lamp holder screwed
completely into the body.)
• Check bulb to make sure that it has not burned out. Replacement bulbs #52364
For more information on product maintenance and maintenance videos, visit
www.thepondboss.net