12 

 

 

0901712

 

Handling 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                 

 

 

 

 

 

 

 

 On / Off 

– Button: Switches the device on or off. 

 If the device is 

switched off it can be started by pressing the „on“ button . If the    

 device is on, this button has to pressed for 1 sec to switch it off.  
 The auto-

off function is regularly on, shown by displaying „Auto-off“. In this   

 case the measurement device will switched off automatically after 10 minutes. 
 By pressing the button      this function can be switched off . 
 
 

CW  Selection of the modulation: By pressing the button the different modulations    
         will be set: 270 Hz, 1 kHz, 2 kHz. 
 
λ      Switches the possible wavelengths: 1310 nm and 1510 nm. The selected    
        wavelength is shown in the display. 
 
 

 

On / Off button 

Power supply 
connection 

Display of 
mains operation 
mode 

 

Charge state of 
the battery 

Displays 

if „auto 

off“  is activated 

Selection of 
wavelength 

 

Activates 
modulation

 

Displays the 
wavelength 

Shows  the 
modulation 

Optical output 
FC/PC 

Summary of Contents for OME 100

Page 1: ...Optischer Testsender Optical test transmitter OME 100 Bedienungsanleitung Operating manual 0901744 V3...

Page 2: ...matische Abschaltfunktion Hohe Stabilit t der Ausgangsleistung M glichkeit des Netzbetriebes Netzteil im Lieferumfang enthalten Lieferumfang 1 x OME 100 Testsender 1 x Aufbewahrungstasche mit Tragegur...

Page 3: ...s nicht den optischen Wandler ffnen um Verschmutzung oder Zerkratzen des SC APC Steckers zu vermeiden 2 Der optische Eingangspegel sollte nicht h her als 30 dBm sein andernfalls wird das optische Modu...

Page 4: ...Es k nnen Batterien oder Akkus 3 x Mignon AA verwendet werden Die Aufladung der Akkus muss in einem externen Ladeger t vorgenommen werden Dauer des Batteriebetrieb ca 45 Stunden Batteriefach Abdeckun...

Page 5: ...h das OME100 automatisch nach ca 10 Minuten aus Um dies zu deaktivieren gen gt ein Tastendruck auf CW Auswahl der Modulation Durch bet tigen des Taster wird zwischen den verschiedenen Modulationen umg...

Page 6: ...gte Ende des PON Kerbe des Steckers beachten 5 Schalten Sie das optische Messger t ein bitte die automatische Abschaltung beachten und gegebenenfalls deaktivieren siehe Seite 5 6 Im Display werden die...

Page 7: ...7 OME 100 7 dBm Ausgangsleistung OSF 800 10 dB D mpfung OME 200 18 dBm Eingangsleistung...

Page 8: ...8 Notizen...

Page 9: ...High stability of the output signal Mains operation Power supply included Included parts 1 x OME 100 test transmitter 1 x Bag with shoulder strap 1 x Manual 3 x Batteries Type AA 1 x Cleaning swabs se...

Page 10: ...it please do not open the optical adapter converter to avoid pollution and scratching of the SC APC connector 2 Input of optical power should not be higher than 3 dBm otherwise the optical modules wil...

Page 11: ...ation Please pay attention It s possible to use battery or accu 3 x Mignon AA The accu charge process must be done in an external charging device Battery operation approx 45 hours Battery case Cover F...

Page 12: ...ally after 10 minutes By pressing the button this function can be switched off CW Selection of the modulation By pressing the button the different modulations will be set 270 Hz 1 kHz 2 kHz Switches t...

Page 13: ...e PON you want to measure Pay attention to the notch 5 Switch the optical measuremrent device on pay attention to the switch off automatic and deactivate this if necessary page 11 6 At the display is...

Page 14: ...14 OME 100 7 dBm Output power OSF 800 10 dB loss OME 200 18 dBm input power...

Page 15: ...15 Notes...

Page 16: ...Subject to change without prior notice Copyright Polytron Vertrieb GmbH Type OME 100 Artikelnummer Article number 9245490 Wellenl nge Wave length 1310 nm 1550 nm Dioden Typ Emitter Type FP LD Ausgang...

Reviews: