background image

Wiring Centre

4

H/W 

This output is used to control a hot water valve via a cylinder 
thermostat
L = Live 
E = Earth 
N = Neutral 
Gr = Grey 
Or = Orange
The auxiliary wires of the valve, usually grey & orange, are wired to the 
Gr & Or terminals.

Zones 1…4 

Zones outputs are clearly marked
L = live out to actuator or valve 
N = neutral to actuator or valve
There are two connections live (L) and neutral (N), both terminals 
marked L are the same and both terminals marked N are the same.
Each zone output corresponds to the thermostat wired in at the  
top of the pcb. 

Connections 
Mains Supply

Power supply into the UFH4ZW which should be fused at 5 amps these 
connections are marked 
L = live or phase 230v AC 50/60Hz 
N = Neutral 
E = Earth 

Heat Enable

This is the main call for heat for the system, there are 3 connections;
LS = Live Supply 
E = Earth 
LR = Live Return
Electrically this is a volt free switch, whatever supply is placed on the 
LS connection, is fed to the LR connection when there is a call for heat.

UFH4ZW Wiring

Summary of Contents for UFH4ZW

Page 1: ...Model UFH4ZW...

Page 2: ...is also included as standard This is the pump valve Output which would normally operate a manifold pump or a manifold valve The H W output provides a 230v hot water enable signal to the valve the auxi...

Page 3: ...ge On the back of the UFH4ZW position the clip in the middle and slide down Points A and B locate in the corresponding holes and lock into place Locate the UFH4ZW onto the DIN rail from the top Pull t...

Page 4: ...als marked L are the same and both terminals marked N are the same Each zone output corresponds to the thermostat wired in at the top of the pcb Connections Mains Supply Power supply into the UFH4ZW w...

Page 5: ...ough a high limit switch placed on the heating manifold to protect against mechanical failure of the manifolds temperature control Fuses Fuse 1 5amp 20mm anti surge fuse this fuse supplies power to al...

Page 6: ...derfloor Heating 1 x Radiator zone Hot Water Manifold Valve Pump connections This equipment should be installed by an appropriately Fully read the instructions for proper wiring before applying power...

Page 7: ...MS N N N N N N N N N N 1 A 1 A 1 A 1 A A1 2 T R 2 T R 2 T R 2 T R 1 T R 1 T R 1 T R 1 T R 2 T R 2 A 2 A 2 A 2 A 1 T R A2 L S L S SL SL SL ZONE 3 HOT WATER ZONE 4 ZONE 2 ZONE 1 L L L L L E E E E L L E...

Page 8: ...ONE 1 MAINS L E N L E N SL L L N N ZONE 2 ZONE 2 L E N SL L L N N L E N LS E LR UFH4ZW Polypipe 230v Thermostat Wiring This equipment should be installed by an appropriately Fully read the instruction...

Page 9: ...THROUGH THE CYLINDER HIGH LIMIT THERMOSTAT ACTUATORS 230V UFH HEATING HOTWATER SmartStat ZONE 3 ZONE 3 L E N SL L L N N ZONE 4 ZONE 4 L E N SL L L N N HOT WATER HOT WATER VALVE L E N SL L E N GR OR Ra...

Page 10: ...Wiring Centre 10 System Configuration PLEASE COMPLETE DURING INSTALLATION UFH4ZWTitle In Use ZoneType ZoneTitle Under Floor Radiator Zone 1 Zone 2 Zone 3 Zone 4 HotWater...

Page 11: ...11 Model UFH4ZW Notes...

Page 12: ...ipe Building Products Broomhouse Lane Edlington Doncaster DN12 1ES Want More Information Call our telephone support team on 01709 772200 Or view technical specifications directly on our website www po...

Reviews: