Range:
GCF100LV-S
Standard
GCF100LV-T
Overrun timer
GCF100LV-HPC
Humidistat and optional overrun timer and pull-cord switch override
OPERATION
Overrun timer adjustment – models fitted with overrun timers only
Before making any adjustments, isolate the fan from the power supply. Remove the front cover and the
body moulding.
Locate the ‘jumper’ on the relevant set of pins to achieve the desired run-on time (see
Diagram 4).
Humidity adjustment – humidistat models only
All GCF humidistat fans automatically sense a rapid change in humidity and adjust accordingly. The
humidity control does not require manual adjustment.
Humidistat fans, when energised for the first time,
will run and time out as part of the stabilising process.
Performance:
19 l/s at 0 Pa – 91 Pa at 0 l/s
Rating:
230V 50Hz 7.4W IPX4 SFP 0.39 W/l/s
This product is double insulated and does not require an earth conductor.
Maximum room temperature 40ºC