3. Connect the power supply cable to the power supply box and prepare and connect a second piece of
cable to link the power supply box to the fan (see wiring diagrams).
4. Remove the domed centre cover from the fan by removing the single screw.
5. Cut an incision into the blanking plug and feed the supply cable through. Connect the cable to the correct
terminals. (see wiring diagrams).
6. Ensure the fan is moving air in the correct direction and bring the duct system to each end of the fan.
Secure the fan to a surface using suitable fixings and seal the duct connections.
Note: All ancillary items can be obtained through Silavent stockists.
Call
+44 (0) 8443 715523
to find your nearest stockist
Wiring Instructions:
It is recommended that the fans are connected into the lighting circuit, with double pole isolation (3mm
minimum contact separation) provided before the room light switch and suitably fused, in accordance with the
latest edition of the IEE Wiring Regulations.
Window mounted fans should be connected to the power supply using a flexible cord with conductors of
maximum size 0.75mm². Wall and ceiling mounted and In-line fans for fixed wiring should be connected to the
power supply through a cable with solid conductors of between 1.0mm² and 1.5mm² only.
IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN
Models
GLA100LV-T
GLA100LV–S
GLA100LV-H
GLA100-PIR
GLA100LV-PC
GLA100LV-HPC
GLD100-T
S/L OR T = Switched Live
L = Permanent Live
N = Neutral
WARNING: ISOLATE ELECTRICITY SUPPLY BEFORE STARTING WORK
MAXIMUM ROOM TEMPERATURE 40ºC