background image

The Programmable Zone Control Packs allow all

rooms to be individually controlled for both time

and temperature.

When using The Single Zone Pack (PB1ZP) no

Actuators are required, however actuators

(PB00401) will be required for all other packs.

A Zone Valve installed on the flow to the manifold

is always required.

The Master Unit provides wiring connections for

The Boiler (incl. Volt Free), Zone Valve, UFH pump,

Valve  actuators and The Programmable Room Stat.

The Power Supply to the unit must come from the

230v - 50Hz Supply from main heating isolator.

The Programmable room stat can be installed

outside wet areas and connected to the Wet area

sensor (PB23020) where this is required.

FLOOR HEA

TING CONTROLS

HOT & COLD PLUMBING & HEATING SYSTEM

Programmable
Control Pack

Master

Connection Unit

Slave Unit

Programmable Room Thermostat

Programmable 
Room Thermostat

Overview

The Programmable Room Thermostat controls and

regulates the room temperature. The thermostats

should be positioned 1·2m from the floor and away

from other heat producing appliances.

Note

Programmable Room Thermostats differ in operation

from conventional Room Controls as they not only set

a maximum room temperature but also set a

minimum temperature that the room temperature is

allowed to fall to.

This is particularly important when controlling floor

heating systems as the heating response is slower

than that of conventional radiators.

Features

• 7 Day Programme

• 5 built in and 2 User Defined Programmes

• Holiday Function

• Frost protection programme

• Battery replacement without loss of programme

Technical Characteristics

Pack Code

4 Zone

4 Zone

Programmable

Master

Slave

Room Thermostat

PB1ZP

1

1

PB4ZP

1

4

PB6ZP

1

1

6

PB8ZP

1

1

8

Measuring Accuracy

0·1°C

Operating Temperature

0°C - 50°C

Ambient Temperature range

5°C - 37°C in steps of 0·5°C

Characteristics of different 

Integral proportional band or

regulations

Static differential

Electrical Protection

Class II – IP30

Feeding & Autonomy

3 batteries AA LR06 1·5 V/> 2 years
(alkaline batteries)

Output

Relay 5A 250V ac