background image

IMPORTANT SAFETY INSTRUCTIONS

1.

READ AND FOLLOW ALL INSTRUCTIONS

7.

SAVE THESE INSTRUCTIONS.

When installing and using this electrical equipment, basic safety precautions should always be followed, including 
the following:

2.

WARNING -

 To reduce the risk of injury, do not permit children to use this product unless they are closely

supervised at all times by an adult who is capable of assisting a child in distress.

3.

WARNING -

 Risk of electrical shock. Connect only to a grounded receptacle protected by a ground-fault

circuit-interrupter (GFCI). A GFCI must be provided in accordance with Section 680-31 of the National Electrical

Code. Contact a qualified electrician if you cannot verify that the receptacle is protected by GFCI.

4.

WARNING - 

To reduce the risk of electrical shock, replace damaged cord (with pump body) immediately.

NEVER bury cord. Locate cord to eliminate abuse or contact from lawn mowers, hedge trimmers, and other
equipment. NEVER use an extension cord to connect unit to electric supply; provide a properly located outlet.

2

2

DISTRIBUTED BY: POLYGROUP LIMITED (MCO)

Customer Service: 

 

(888) 919-0070 •

 

www.polygroupstore.com

UV SANITIZER (UVS-1012) OWNER’S MANUAL

FOR ABOVE GROUND QUICK SET® SWIMMING POOLS

LIMITED WARRANTY

     Polygroup Limited (Macao Commercial Offshore), (hereinafter “Polygroup”) warrants to the original purchaser only, 

the UV Sanitizer against defects in material and workmanship for 180 days from the date of purchase. Original 
Purchaser must retain proof of such purchase in the form of an original store sales receipt and must produce such 
upon request by Polygroup or its designated agents.  Warranty claims cannot be processed without a valid proof of 
purchase.

      This Limited Warranty applies only to the original purchaser of the product and is limited solely to the repair or 

replacement of the product, to be decided in Polygroup’s sole discretion.  Consequential damages, including claims 
for loss of water, pool chemicals, damage, or labor are not covered under this Limited Warranty.

   This Warranty will be declared invalid should the Purchaser modify or repair the product themselves or by 

     unauthorized persons; use non-Polygroup parts or accessories with the product; use the product in contravention 

of the Manufacturers Instructions; use improper voltage; abuse the product in any way; or through accident or 
negligence.  Normal wear-and-tear is not covered under this Warranty, nor are acts of God outside the control of 
Polygroup.

  IN NO EVENT SHALL POLYGROUP, THEIR AUTHORIZED AGENTS, RELATED ENTITIES, OR EMPLOYEES BE LIABLE TO THE 

BUYER OR ANY OTHER PARTY FOR DIRECT OR CONSEQUENTIAL DAMAGES. Some states or countries, or others 
jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above 

     limitation or exclusion may not apply to you.

     Should you encounter a problem with your Polygroup Product, please do not return the product to the place or 

purchase.  All Warranty claims must be made directly to Polygroup.  Prior to contacting Customer Service, please 
first review the Troubleshooting Guide in the Installation Manual, or review the FAQ at www.polygroup.com . If you 
are still unable to correct the problem, please contact Polygroup customer service at (888) 919-0070. Have the 
product type and your purchase receipt ready.  Our Customer Service Representative will assist you in resolving the 
problem.  You may be asked to return all or part of the product for inspection and/or repair.  Do not return any 
product to Polygroup without a Return Authorization number.

2X

2X

4X

5.

CAUTION -

 For continued protection against possible electric shock, use only original equipment

manufactured (OEM) parts for your replacement requirements.

IMPORTANT SAFETY INSTRUCTIONS
PRELIMINARY STEPS
EXPLODED DIAGRAM
INSTALLATION
DISASSEMBLY AND STORAGE
MAINTENANCE
TROUBLE SHOOTING GUIDE
UV TUBE REPLACEMENT PROCEDURES
PARTS & ACCESSORIES

2
3
4
5
6
6
6
7
8

6. Modifications are not approved by the party responsible for compliance could void user’s authority to

operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off an on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Summary of Contents for UVS-1012

Page 1: ...ts of God outside the control of Polygroup IN NO EVENT SHALL POLYGROUP THEIR AUTHORIZED AGENTS RELATED ENTITIES OR EMPLOYEES BE LIABLE TO THE BUYER OR ANY OTHER PARTY FOR DIRECT OR CONSEQUENTIAL DAMAGES Some states or countries or others jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Should you...

Page 2: ... Ea 3 1 READ ALL INSTRUCTIONS CAREFULLY and get a thorough understanding of what is required to assemble to your Type of Pool and Filter System 2 Before you begin to assemble the UV Sanitizer identify count and check all parts needed for assembly Refer to the PARTS LIST Page 8 3 It is recommended that you have some PETROLEUM JELLY on hand for lubricating the gaskets 1 Installer shall follow writte...

Page 3: ...e is protected by a GFCI Receptacle must be at least 10 feet away from pool Do not use an extension cord to connect unit to electric supply provide a properly located outlet Do not bury the cord NOTE The UV Sanitizer consists of UV Sanitizer Power Adapter Hardware Bag Hose Adapters Hose Clamps and Water Hoses The UV Sanitizer can be used with Skimmer Pump Fig 1 or RP Pump Fig 2 filter system A Rem...

Page 4: ...emove the UV Tube Socket from the defective UV Tube Remove the defective UV Tube 7 Insert a new UV Tube Plug in the UV Tube Socket to the UV Tube Put back the UV Tube End Cover Tighten the UV Tube End Cover with screws Put back the Bottom Cover Tighten the Bottom Cover with screws Done 1 WARNING To reduce the risk of electric shock the parts should be completely dry before servicing Disconnect fro...

Reviews: