Rack-Mount Installation
You can install the Polycom VBP 7301 in a 19” rack using the rack mount kit
supplied with the product.
Note
Important
Before installing the device in a rack, take note of the following conditions:
Elevated Operating Ambient
—If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature specified by the manufacturer.
Reduced Air Flow
—Installation of the equipment in a rack should be such
that the amount of airflow required for safe operation of the equipment is not
compromised.
Mechanical Loading
—Mounting of the equipment in the rack should be such
that a hazardous condition is not achieved due to uneven mechanical loading.
Circuit Overloading
—Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits
might have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when addressing
this concern.
Reliable Earthing
—Reliable earthing of rack-mounted equipment should be
maintained. Particular attention should be given to supply connections other
than direct connections to the branch circuit (for example, use of power
strips).
Install the Polycom VBP 7301 in a Rack
1.
Attach the rack mount ears to both sides of the Polycom VBP 7301 chassis
with the supplied screws.
2.
Install the chassis in the rack with rack mount screws (not included).