Audio/Video 
Calls  

 

If you dial an incomplete IP address for a video call (for example, 172.16.254.), you may hear 
a ringing sound for approximately 90 seconds. Until the ringing ceases, you will be unable to 
place another call. 

Content 

If you share content using a laptop, for best results, set its input resolution to 1024x768 and 
its refresh rate to 75 Hz. This will ensure that the content image renders correctly. 

Document 
Cameras 

The Eye-10 document camera used in some custom solutions does not support the Freeze 
function that is available for other document camera models. 

Touch Panel/ 
User Interface 

If you press the 

Content

 button on the Touch Panel when no content source (such as a 

laptop) is connected to the RPX with the VGA cable, the Primary HDX codec will generate a 
hidden message on the Primary wall screen. The message states "PC input resolution and/or 
refresh rate not supported.” This message will not be visible onscreen because the RPX is 
programmed to picture mute all wall screens when the system is not in a call. If you establish 
a video call while the message is activated, the call will take longer than usual to connect.  

To avoid this issue, wait three seconds (during which time the message will time out) before 
placing a video call from the Touch Panel. 

In an audio call from an RPX to a cellular phone or analog phone, if the remote user 
disconnects the call first, the Touch Panel continues to show the audio call as in progress.  

To avoid this issue, manually press the 

Hang Up

 button after each audio call is 

completed. The RPX will not accept incoming audio or video calls when the 

Hang Up

 button 

is off hook.   

When searching for a site in the global directory with the Enhanced UI, up to nine characters 
can typically be displayed on the screen. However, depending on the width of the letters in 
the name, more or less of the site name may be truncated. 

With Meeting Composer, when dialing a phone number with more than 10 digits, or dialing 
any other long string such as extension@IP_address (ex: [email protected]), the 
string will likely be truncated when displayed in the right-hand pane of the Touch Panel. 

If you place a point-to-point call to an RMX Virtual Meeting Room (VMR) and then add an 
audio-only site to the call, the two columns on the left side of the Meeting Composer screen 
in the Enhanced UI will go blank and the icons at the top of the columns will become grayed-
out. 

When Polycom Conferencing for Microsoft Outlook (PCO) is used to schedule multiple 
meetings and you select one of the meetings on the Touch Panel, the details for that meeting 
display on the left side of the Touch Panel screen. If that meeting is cancelled, it is removed 
from the meeting list; however, the details of the cancelled meeting are still displayed on the 
left side of the Touch Panel screen. 

To fix this issue, simply select a different meeting from the meeting list. 

 

Summary of Contents for RPX HD 200 Series

Page 1: ...For Users 7 For Administrators 9 Where to Get the Latest Product Information 10 Copyright Information 2011 Polycom Inc All rights reserved 3725 25796 012 B January 2011 Polycom Inc 4750 Willow Road P...

Page 2: ...which replaces the Delta VW7008 projector beginning in the first quarter of 2011 Information on the configuration of these and other RPX features is provided in the Polycom Immersive Telepresence ITP...

Page 3: ...l and use the Telepresence Tool 5 Configure the Immersive Telepresence features 6 Align and calibrate the projectors if you upgraded the projector firmware 7 Configure align and match the cameras if y...

Page 4: ...st do the following a In the Select Model field select the RPX system model b In the Select Main Display field select the video format for the main displays installed in the room c In the Select Conte...

Page 5: ...operties 5 Click OK 6 Press the Right Arrow button on the screen to select Scaling 7 Click OK 8 Select Full Screen 9 Click OK 10 If needed press the Auto Sync button to make the content fill the scree...

Page 6: ...call with the Enhanced UI the system may have automatically dialed the number before you pressed the Connect button When viewing an RPX system in a 1080p multipoint call with an RMX 2000 or RMX 4000...

Page 7: ...d this issue verify that the projectors are powered up before placing or receiving any video calls If the projectors are in sleep mode when a video call comes in any codecs that are not being used wil...

Page 8: ...log phone if the remote user disconnects the call first the Touch Panel continues to show the audio call as in progress To avoid this issue manually press the Hang Up button after each audio call is c...

Page 9: ...suffixes 1 2 3 and 4 for your audio speed dial name entries Using these suffixes may cause the system to incorrectly interpret them as an ITP suite instead of distinct audio speed dial entries Avoid c...

Page 10: ...to reboot power up the AV2 System Controller after the HDX reboots powers up as part of the reset process or when recovering from a power failure Placing a call without rebooting the AV2 System Contr...