Modes of Operation:

Handset Only Mode

 (Audio through handset only with

volume control):

 

Auto Answer Mode

: Call comes in, video is auto-

  answered, and audio is muted until handset is picked
 up.

 

Standard Answer Mode

: Call is only answered when

  the handset is picked up.

 

Auto Dial Mode

: System audio dials a preset number

  when the handset is lifted. Preset is labeled “auto dial.”
  Configure Favorite Entry with First Name: 

Auto 

and

  Last Name: 

Dial

.

 

Hang Up Call

: System hangs up a call when the

  handset is placed on hook, with a built-in three
  second delay in case of accidental user error.

Hands-Free Mode

 (No handset, therefore no volume

control): System auto answers only. No other features.
The call is disconnected by the far-end hanging up the
call or using the ir remote locally. Audio through
speakers only.

Both Handset and Hands-Free Mode

 (Includes volume

control): System auto answers with audio through
speakers. Pick up handset and audio goes to handset
only (privacy). Pre-define upon installation: To
eliminate the handset from hanging up calls (h
hands free operation), set the following in Favorite
entry, First Name: 

handset

, Last Name: 

hangupoff , 

to not

disconnect the call when the handset is returned to the
cradle. A dummy IP address may be required to store
Favorite entry. Use 127.0.0.1 or other.

Mains Input Rating:

Voltage: 100-240VAC, 50-60Hz
Current: 2.7A (max)

Physical size and weight:

23-1/2” W x 19” H x 6-5/8” D without handset
27” W x 19” H x 6-5/8” D with handset
55 lbs.

6

Polycom® RealPresence® Video Protect 500 Setup Sheet

Regulatory Notices:

 

This equipment is intended for indoor use only.

   Do not use a power cord that is damaged. This could cause

 

fire or electric shock. Contact the manufacturer for a

 

replacement cord, if necessary.

   Only use a power cord which is appropriately rated and

 

approved relevant to the country of use.

   When connecting to the mains supply, connect only to an

 

earthed supply outlet which is installed near the equipment

 

and is easily accessible.

  

If the mains supply is required to be made directly to the

 

building electrical installation, only a qualified electrician

 

should carry out this work in accordance with local wiring

 

rules and regulations.

   Keep ventilation openings free from any obstructions.

  The ambient operating temperature rating of this equipment

 is 

0 - 40ºC and should not be exceeded.

  

Do not immerse the system in any liquid or place any liquids

 

on it.

  

Do not spray liquids directly onto the system when cleaning.

 

Always apply the liquid first to a static-free cloth.

  

For further information concerning the individual components

 

of this equipment, please refer to the respective product

 literature.

  

For support or service, please contact your Polycom®

 

distributor or go to Polycom Support at

 www.polycom.com/support. 

Summary of Contents for RealPresence Video Protect 500

Page 1: ...concrete anchors 1 4 20 x 1 1 4 hex cap screws and 1 4 washers not supplied If you are mounting to a surface other than brick or concrete use appropriate mounting hardware or seek professional assistance The installer should have a plan for connecting the system using one of the following options A hole drilled in the wall with network and AC ready for system AC wall outlet and or a LAN wall outle...

Page 2: ...3 5mm cable from the codec Audio Out port to the display Audio In port Also replace the protective camera lens with the lens that has pre drilled holes Open the enclosure and hang the enclosure on the wall using five screws per side Note that two screws on each side align with two keyhole slots in each side of the enclosure 4 5 6 Remove the codec mounting bracket from the enclosure by removing the...

Page 3: ...ckets and screws Attach the power supply to the enclosure using the supplied bracket and screws 8 Attach the cables to the codec Most cables are pre wired and labeled Refer to the wiring diagrams at the end of this document for details 7 Using the supplied zip ties secure the camera cable to the monitor mounting bracket 10 ...

Page 4: ...network cable to the codec or connect a bare wire directly to the network junction block 13 Connect the camera cable to the codec 11 12 To securely store the remote use the supplied Velcro to attach the remote to the bracket on the inside cover of the Video Protect system Before storing the remote inside the unit Polycom recommends that you remove the USB rechargeable battery by This prevents the ...

Page 5: ... the following codec settings Admin Settings General Settings Serial Ports Mode RS 232 Mode Control Baud Rate 9600 Parity None Data Bits 8 Stop Bits 1 RS 232 Flow Control None Login Mode None The Video Protect 500 does not support the use of passwords on the serial port Admin Settings Audio Video Audio Audio Input Playback Options Handset Audio Input Level 5 default Admin Settings General Settings...

Page 6: ...27 0 0 1 or other Mains Input Rating Voltage 100 240VAC 50 60Hz Current 2 7A max Physical size and weight 23 1 2 W x 19 H x 6 5 8 D without handset 27 W x 19 H x 6 5 8 D with handset 55 lbs 6 Polycom RealPresence Video Protect 500 Setup Sheet Regulatory Notices This equipment is intended for indoor use only Do not use a power cord that is damaged This could cause fire or electric shock Contact the...

Page 7: ...7 Polycom RealPresence Video Protect 500 Setup Sheet Shield Wiring Diagram ...

Page 8: ...8 Polycom RealPresence Video Protect 500 Setup Sheet Handset Wiring Diagram ...