background image

 

 

OFF 

00s < x < XXs 

Nothing 

ON 

00s < x < 60s 

Search for source base/repeater 

ON 

60s < x < XXs 

Search for any base/repeater in the system 

 

Button 

In the below table the action of the button press is presented. 

Button 

Press 

Action 

00s < x < 02s 

Nothing 

02s < x < 06s 

Delete registration 

Old registration is deleted, and a new registration procedure is 
started. 

18s < x < 60s 

Enable or disable repeater monitor beep tone in handset during call. 

60s < x < XXs 

Nothing 

 

LED 

LED 

Indication 

Action 

GREEN 

Off 

Power Off 

GREEN 

Slow flash 

Unlocked, Searching for base station 

GREEN 

Double flash 

Registration/subscription mode and searching for open base station – 
registering procedure. 

GREEN 

Steady on 

Locked to base station and ready for use - idle 

RED 

Off 

No handset relayed by repeater 

RED 

n

 flash 

n

 handset relayed by repeater 

RED 

Steady on 

1. Registration procedure timed out after 5 min. 

2: When key is held pressed the LED will light up in 2 sec. to indicate 
that releasing the key will delete registration, LED turns off after 4 
more sec. 

RED/GREEN 

Flashing 
Red/Green 

Recovery mode – repeater is locked to base station/repeater without 
repeater mode activated. 

1: Sync. Source base station/Repeater not found (Manual mode). 

2: Timeout during RPN allocation due to busy base station/Repeater. 

 

 

 
 
 
 

Summary of Contents for Rove R8

Page 1: ...Rove R8 REPEATER USER GUIDE ...

Page 2: ... are provided about Poly products Poly makes no representations with respect to completeness or accuracy of the contents of this publication and reserves the right to make changes to product descriptions usage etc at any time without notice No license whether express implied to any intellectual property rights are granted by this publication Confidentiality This document should be regarded as conf...

Page 3: ... on how to install register and manage Poly repeaters Document History REVISION AUTHOR ISSUE DATE COMMENTS 1 0 MLE 16 09 2020 What is new What new features have been added VERSION FEATURE V515 Main topics Installation Locate automatic Manual registration Firmware update LED indications ...

Page 4: ...o the next step Every shipped repeater package box contains the following items 1 x Power supply 1 x Repeater 1 x Table stand 1 x Safetysheet Damage Inspection The following are the recommended procedure for you to use for inspection 1 Examine all relevant components for damage 2 Make a defective on arrival DOA report or RMA to the operator Do not move the shipping carton until the operator has ex...

Page 5: ... on a wall in a height less than 2 meters Screws and Anchors needed Not supplied by Poly 2x Screws Screw wall mount M3 5x31 2x Anchors Length 29 6mm OD 6 0mm ID 4 8mm NOTE The repeater should be mounted on a wall not higher than 2 meters 3 4 Recommended external DC adapters Part Nr Description Manufacturer Type S005CAV0500100 SMPS 100 240VAC 5V 1000mA with USB A Ten Pao International LTD EU S005CA...

Page 6: ...most cases when adding repeaters to a multi cell system Manual registration allows to determine what base stations the repeater must connect to Register repeater s Local Automatic NOTE Do not power on the repeaters before they have been added on the base station NOTE When adding first repeater the base station s will reboot this is because encryption is being enabled the same goes if all repeaters...

Page 7: ...N02 and third RPN03 3 repeaters maximum per base MULTI CELL SYSTEM Bases are increment by 2 2 in hex means first base RPN00 second base RPN04 etc in between RPN01 02 03 addressed for repeaters at Primary base and 05 06 07 addressed for Secondary base 3 repeaters maximum per base NAME IPIE Name and IPIE number of the repeater DECT SYNC MODE DECT Sync mode Manually or Automatic STATE State of the re...

Page 8: ...cryption Step 1 To register repeater s navigate to the Repeater page Screen shot Step 2 Click Add Repeater and select Manually from the dropdown Screen shot Step 3 Give the repeater a name and press save Step 4 select what base station the repeater needs to register to DECT sync source drop down In this case there are three base stations in the multicell RPN00 RPN04 and RPN08 and three repeaters c...

Page 9: ... repeater ERROR The repeater will choose the first available slot on the selected base station RPN x The repeater connects to RPN x of the chosen base station E g Base station RPN04 RPN1 repeater then the repeater connects to RPN5 Screen shot ...

Page 10: ...Firmware update The repeaters are updated over air Step 1 Navigate to Firmware Update page Step 2 Enter Firmware Update server address Firmware path and DECT402x firmware version Screen shot ...

Page 11: ...Input s 8 bit string length E g 400 Note Value version 0 will disable firmware upgrade Note Two handset types will be serial firmware upgraded First type 8630 then type 8430 REQUIRED BRANCH Empty Branch of firmware to be upgraded or downgraded handset repeater or base station Valid Input s 8 bit string length E g 01 NOTE Repeater firmware do not follow the normal version numbers LED and button Pow...

Page 12: ...for base station GREEN Double flash Registration subscription mode and searching for open base station registering procedure GREEN Steady on Locked to base station and ready for use idle RED Off No handset relayed by repeater RED n flash n handset relayed by repeater RED Steady on 1 Registration procedure timed out after 5 min 2 When key is held pressed the LED will light up in 2 sec to indicate t...

Page 13: ...d and operated with minimum distance 20cm between the radiator your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter located or operating in conjunction with any other antenna or transmitter ISEDC Warning This device complies with ISEDC licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may ...

Reviews: